Skip to main content
Michigan water passport ยท EPA MI0003741

Lake Charter Township Water Quality, PFAS & Utility Report (MI0003741)

Lake Charter Township (MI0003741) is a Local Government public water utility serving 4,177 residents in Berrien, Michigan primarily from surface water. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while all 120 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 62.4% of homes across 5 served ZIP codes predate 1980.

EPA PWSID
MI0003741
Population Served
4,177
Water Source
Surface Water
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Filtration & pipe verdict for Lake Charter Township

Drawing surface water across Berrien, Lake Charter Township uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 15,603 housing units in Lake Charter Township's 5 ZIP codes (median value $246,080), 62.4% predates 1980 (31.4% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Are Lake Charter Township's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Lake Charter Township's network.

EPA SDWA and local housing profile for Lake Charter Township (MI0003741)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership MI0003741 (Local Government) Active CWS Last sanitary visit: 08/15/2024
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 4,177 residents #253 in Michigan Counties: Berrien
Served ZIP Codes 49101, 49106, 49107, 49125, 49127 5 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 62.4% (31.4% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 7.6 GPG (Hard) >= 7.0 GPG = Hard Size ion-exchange resin on local grain test

Did MI0003741 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Lake Charter Township against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for MI0003741
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

How Does Lake Charter Township Compare to Peer Michigan Utilities?

Review four nearby Michigan community water utilities matched by service rank inside Michigan's 291-utility public water catalog.

Nearby community water systems in Michigan for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Wayland (MI0006940) Wayland 4,435 Groundwater 0
Hannahville Community (055293611) Michigan 4,382 Groundwater 0
Roosevelt Park (MI0005800) Roosevelt Park 4,172 Surface / Mixed 0
Livingston Community Water Authority (MI0003929) Livingston 4,152 Groundwater 0

When Should Lake Charter Township Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Berrien; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7.6 GPG) and add scale inhibition on groundwater feeds.

Homeowner Water Quality FAQs for Lake Charter Township (MI0003741)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Where does Lake Charter Township (MI0003741) source drinking water?

EPA ECHO classifies Lake Charter Township (MI0003741) as a Surface Water community system serving 4,177 residents across Berrien. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Were PFAS compounds detected in Lake Charter Township UCMR 5 testing?

Federal UCMR 5 sampling covering 120 laboratory tests for Lake Charter Township reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Could homes served by Lake Charter Township still face lead solder or older pipe risks?

Across the 5 ZIP codes served by Lake Charter Township, approximately 62.4% of residential housing units were built before 1980 (31.4% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019โ€“2023 5-Year Summary File — U.S. Census Bureau, 2019โ€“2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks