Skip to main content
Utility quality file · Utica, MI (MI0006760)

Utica, City Of Water Quality, PFAS & Utility Report (MI0006760)

Supplying 5,059 customers across Macomb, Michigan, Utica, City Of (EPA ID MI0006760) relies on surface water purchased for daily municipal flow. Current federal compliance files record zero EPA health violations alongside 1 monitoring/reporting notice; meanwhile UCMR 5 samples measured 4.8 ppt for PFNA (exceeding the 4.0 ppt federal rule), and 56.3% of homes across 1 served ZIP code predate 1980.

EPA PWSID
MI0006760
Population Served
5,059
Water Source
Surface Water
Max UCMR 5 PFAS
4.8 ppt (PFNA)
3-Yr Health Flags
0 Health Viol.
Tap treatment summary — MI0006760

Drawing surface water across Utica, Utica, City Of uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 4.8 ppt for PFNA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 12,936 housing units in Utica, City Of's 1 ZIP code (median value $248,700), 56.3% predates 1980 (22.2% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Is Utica, City Of's Municipal Water Supplied and Regulated?

Review Utica, City Of's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Utica, City Of (MI0006760)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership MI0006760 (Local Government) Active CWS Last sanitary visit: 10/27/2021
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 5,059 residents #234 in Michigan Counties: Macomb
Served ZIP Codes 48317 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 56.3% (22.2% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 1 rule violation (2 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 7.6 GPG (Hard) >= 7.0 GPG = Hard Size ion-exchange resin on local grain test

What Do Federal PFAS Lab Results Show for Utica, City Of?

See how Utica, City Of (MI0006760) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for MI0006760
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA 4.8 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Which Nearby Michigan Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Michigan.

Nearby community water systems in Michigan for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Musk Co Northside Water System (MI0004577) Muskegon 5,133 Surface / Mixed 0
Rochester East (MI0005723) Rochester 5,100 Surface / Mixed 0
Caro, City Of (MI0001130) Tuscola 5,029 Groundwater 0
Davison, City Of (MI0001720) Davison 5,000 Groundwater 0

When Should Utica, City Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Utica; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7.6 GPG) and add scale inhibition on groundwater feeds.

Practical Drinking Water Questions for Utica Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Utica, City Of draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Utica, City Of (MI0006760) as a Surface Water Purchased community system serving 5,059 residents across Macomb. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

What did federal UCMR 5 sampling measure in MI0006760?

Yes—UCMR 5 laboratory testing for MI0006760 recorded 1 PFAS detections peaking at 4.8 ppt (PFNA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

How does local home age affect plumbing risk inside MI0006760's service area?

Across the 1 ZIP codes served by Utica, City Of, approximately 56.3% of residential housing units were built before 1980 (22.2% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks