Skip to main content
Community water audit · MS0490010 in MS

City Of Winona Water Quality, PFAS & Utility Report (MS0490010)

Homeowners connected to City Of Winona (MS0490010) in Winona, Mississippi receive ground water across a 5,071-person distribution network. EPA SDWIS records document zero EPA health violations alongside 2 monitoring/reporting notices; under UCMR 5 monitoring, all 60 federal UCMR 5 PFAS lab runs tested non-detect, and 55.7% of homes across 1 served ZIP code predate 1980.

EPA PWSID
MS0490010
Population Served
5,071
Water Source
Groundwater
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — City Of Winona

Drawing surface water across Winona, City Of Winona uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 3,523 housing units in City Of Winona's 1 ZIP code (median value $124,700), 55.7% predates 1980 (28.5% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by City Of Winona?

Examine City Of Winona's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Montgomery.

EPA SDWA and local housing profile for City Of Winona (MS0490010)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership MS0490010 (Local Government) Active CWS Last sanitary visit: 06/24/2025
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 5,071 residents #133 in Mississippi Counties: Montgomery
Served ZIP Codes 38967 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 55.7% (28.5% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 2 rule violations (10 qtrs) Zero health flags target 2456=Total Haloacetic Acids (Haa5), 2950=Tthm
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in City Of Winona Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify MS0490010's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for MS0490010
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest Mississippi Community System Peers?

Compare four other Mississippi utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Mississippi for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Nts Utility Association (MS0380028) Lauderdale 5,103 Groundwater 0
Fisher Ferry Water District (MS0750004) Warren 5,094 Groundwater 0
Clayton Village W/A #1-East (MS0530006) Oktibbeha 4,984 Groundwater 0
City Of Biloxi-French (MS0240036) Biloxi 4,968 Groundwater 0

When Should City Of Winona Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Winona; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: MS0490010

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does City Of Winona's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies City Of Winona (MS0490010) as a Ground Water community system serving 5,071 residents across Montgomery. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Should City Of Winona homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 60 laboratory tests for City Of Winona reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Does EPA's 10 ppb LCRI lead rule apply to houses on City Of Winona?

Across the 1 ZIP codes served by City Of Winona, approximately 55.7% of residential housing units were built before 1980 (28.5% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks