Unh/Durham Water Sys Water Quality, PFAS & Utility Report (NH0691010)
Unh/Durham Water Sys (NH0691010) is a State Or Territorial Government public water utility serving 16,000 residents in Durham, New Hampshire primarily from surface water. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while all 180 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 46.9% of homes across 2 served ZIP codes predate 1980.
- EPA PWSID
- NH0691010
- Population Served
- 16,000
- Water Source
- Surface Water
- Max UCMR 5 PFAS
- 0 ppt Detected
- 3-Yr Health Flags
- 0 Health Viol.
Drawing surface water across Durham, Unh/Durham Water Sys uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.
Across 5,774 housing units in Unh/Durham Water Sys's 2 ZIP codes (median value $459,600), 46.9% predates 1980 (23.0% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
What Are Unh/Durham Water Sys's Source Water, Population, and Pipe Risk Metrics?
Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Unh/Durham Water Sys's network.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NH0691010 (State Or Territorial Government) | Active CWS | Last sanitary visit: 10/24/2025 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 16,000 residents | #14 in New Hampshire | Counties: Strafford |
| Served ZIP Codes | 03824, 03861 | 2 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 46.9% (23.0% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |
Did NH0691010 Detect PFAS Under EPA UCMR 5 Sampling?
Compare measured UCMR 5 laboratory results for Unh/Durham Water Sys against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
How Does Unh/Durham Water Sys Compare to Peer New Hampshire Utilities?
Review four nearby New Hampshire community water utilities matched by service rank inside New Hampshire's 46-utility public water catalog.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Laconia Water Works (NH1281010) | Laconia | 17,125 | Surface / Mixed | 0 |
| Hudson Water Dept (NH1201010) | Hudson | 16,700 | Groundwater | 0 |
| Seabrook Water Dept (NH2111010) | Seabrook | 14,000 | Groundwater | 0 |
| Lebanon Water Dept (NH1321010) | Lebanon | 13,600 | Surface / Mixed | 0 |
When Should Unh/Durham Water Sys Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in Durham; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Homeowner Water Quality FAQs for Unh/Durham Water Sys (NH0691010)
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Where does Unh/Durham Water Sys (NH0691010) source drinking water?
EPA ECHO classifies Unh/Durham Water Sys (NH0691010) as a Surface Water community system serving 16,000 residents across Strafford. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.
Were PFAS compounds detected in Unh/Durham Water Sys UCMR 5 testing?
Federal UCMR 5 sampling covering 180 laboratory tests for Unh/Durham Water Sys reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.
Could homes served by Unh/Durham Water Sys still face lead solder or older pipe risks?
Across the 2 ZIP codes served by Unh/Durham Water Sys, approximately 46.9% of residential housing units were built before 1980 (23.0% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019โ2023 5-Year Summary File — U.S. Census Bureau, 2019โ2023 5-Year Estimates (retrieved 2026-11-25)