Hopatcong Water Dept Water Quality, PFAS & Utility Report (NJ1912001)
Ranked #185 of 243 major community water utilities in New Jersey, Hopatcong Water Dept (NJ1912001) delivers ground water to 7,224 people around Hopatcong Boro-1912. Public records indicate zero EPA health violations alongside 4 monitoring/reporting notices and note that UCMR 5 samples measured 9.9 ppt for PFOA (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.
- EPA PWSID
- NJ1912001
- Population Served
- 7,224
- Water Source
- Groundwater
- Max UCMR 5 PFAS
- 9.9 ppt (PFOA)
- 3-Yr Health Flags
- 0 Health Viol.
Drawing surface water across Hopatcong Boro-1912, Hopatcong Water Dept uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 9.9 ppt for PFOA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.
Across 4,917 housing units in Hopatcong Water Dept's 1 ZIP code (median value $316,900), 86.3% predates 1980 (45.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
Which Compliance and Housing Indicators Define NJ1912001?
These verified utility measurements pair EPA SDWIS facility data for Hopatcong Water Dept with Census housing vintage across its 1 served ZIP codes.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NJ1912001 (Local Government) | Active CWS | Last sanitary visit: 10/29/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 7,224 residents | #185 in New Jersey | Counties: Sussex |
| Served ZIP Codes | 07843 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 86.3% (45.6% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 4 rule violations (12 qtrs) | Zero health flags target | 3014=E. Coli, 4000=Gross Alpha, Excl. Radon And U, 5000=Lead And Copper Rule |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |
How Do Hopatcong Water Dept PFAS Levels Stack Up Against 4.0 ppt Rules?
EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Hopatcong Water Dept's monitored results below.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 9.9 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
What Do Neighboring Community Water Systems Report in New Jersey?
Cross-check four peer New Jersey water utilities to see how Hopatcong Water Dept ranks by system size, groundwater reliance, and EPA notices.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Keyport Water Dept (NJ1322001) | Keyport Boro-1322 | 7,500 | Surface / Mixed | 0 |
| Fairfield Water Dept (NJ0707001) | Fairfield Boro-0707 | 7,400 | Surface / Mixed | 0 |
| Rockaway Boro Water Dept (NJ1434001) | Denville Twp.-1408, Rockaway Boro-1434, Rockaway Twp.-1435 | 7,066 | Groundwater | 0 |
| Milltown W Dept (NJ1212001) | East Brunswick Twp.-1204, Milltown Boro-1212, North Brunswick Twp.-1215 | 7,000 | Surface / Mixed | 0 |
When Should Hopatcong Water Dept Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in Hopatcong Boro-1912; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Key Questions About Tap Water From Hopatcong Water Dept
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
What water source serves the 7,224 customers under EPA ID NJ1912001?
EPA ECHO classifies Hopatcong Water Dept (NJ1912001) as a Ground Water community system serving 7,224 residents across Sussex. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.
How do Hopatcong Water Dept PFAS levels compare to EPA's 4.0 ppt federal limit?
Yes—UCMR 5 laboratory testing for NJ1912001 recorded 4 PFAS detections peaking at 9.9 ppt (PFOA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.
What pipe materials should homeowners served by Hopatcong Water Dept inspect?
Across the 1 ZIP codes served by Hopatcong Water Dept, approximately 86.3% of residential housing units were built before 1980 (45.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)