Isleta Eastside Water Quality, PFAS & Utility Report (063501109)
Isleta Eastside (063501109) is a Tribal Government public water utility serving 8,941 residents in New Mexico, New Mexico primarily from ground water. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while all 60 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 63.7% of homes across 4 served ZIP codes predate 1980.
- EPA PWSID
- 063501109
- Population Served
- 8,941
- Water Source
- Groundwater
- Max UCMR 5 PFAS
- 0 ppt Detected
- 3-Yr Health Flags
- 0 Health Viol.
Drawing surface water across New Mexico, Isleta Eastside uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.
Across 24,414 housing units in Isleta Eastside's 4 ZIP codes (median value $240,533), 63.7% predates 1980 (27.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
What Are Isleta Eastside's Source Water, Population, and Pipe Risk Metrics?
Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Isleta Eastside's network.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | 063501109 (Tribal Government) | Active CWS | Last sanitary visit: 10/23/2024 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 8,941 residents | #42 in New Mexico | Counties: New Mexico |
| Served ZIP Codes | 87022, 87042, 87068, 87105 | 4 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 63.7% (27.8% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |
Did 063501109 Detect PFAS Under EPA UCMR 5 Sampling?
Compare measured UCMR 5 laboratory results for Isleta Eastside against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
How Does Isleta Eastside Compare to Peer New Mexico Utilities?
Review four nearby New Mexico community water utilities matched by service rank inside New Mexico's 79-utility public water catalog.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Bloomfield Water Supply System (NM3510124) | Bloomfield | 9,536 | Surface / Mixed | 0 |
| Moongate Water System (NM3572007) | Organ | 9,170 | Groundwater | 0 |
| Lee Hammond Water (NM3500624) | Bloomfield | 8,817 | Surface / Mixed | 0 |
| Anthony W&Sd (NM3511207) | Anthony | 8,691 | Groundwater | 0 |
When Should Isleta Eastside Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in New Mexico; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Homeowner Water Quality FAQs for Isleta Eastside (063501109)
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Where does Isleta Eastside (063501109) source drinking water?
EPA ECHO classifies Isleta Eastside (063501109) as a Ground Water community system serving 8,941 residents across New Mexico. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.
Were PFAS compounds detected in Isleta Eastside UCMR 5 testing?
Federal UCMR 5 sampling covering 60 laboratory tests for Isleta Eastside reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.
Could homes served by Isleta Eastside still face lead solder or older pipe risks?
Across the 4 ZIP codes served by Isleta Eastside, approximately 63.7% of residential housing units were built before 1980 (27.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019โ2023 5-Year Summary File — U.S. Census Bureau, 2019โ2023 5-Year Estimates (retrieved 2026-11-25)