Skip to main content
Community water audit · NM3518025 in NM

Las Vegas (City Of) Water Quality, PFAS & Utility Report (NM3518025)

Homeowners connected to Las Vegas (City Of) (NM3518025) in Las Vegas, New Mexico receive surface water across a 14,530-person distribution network. EPA SDWIS records document zero EPA health violations alongside 6 monitoring/reporting notices; under UCMR 5 monitoring, all 66 federal UCMR 5 PFAS lab runs tested non-detect, and 60.8% of homes across 1 served ZIP code predate 1980.

EPA PWSID
NM3518025
Population Served
14,530
Water Source
Surface Water
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Las Vegas (City Of)

Drawing surface water across Las Vegas, Las Vegas (City Of) uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 9,699 housing units in Las Vegas (City Of)'s 1 ZIP code (median value $169,000), 60.8% predates 1980 (35.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Las Vegas (City Of)?

Examine Las Vegas (City Of)'s raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in San Miguel.

EPA SDWA and local housing profile for Las Vegas (City Of) (NM3518025)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership NM3518025 (Local Government) Active CWS Last sanitary visit: 12/05/2024
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 14,530 residents #25 in New Mexico Counties: San Miguel
Served ZIP Codes 87701 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 60.8% (35.3% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 6 rule violations (12 qtrs) Zero health flags target 0200=Surface Water Treatment Rule, 0300=Interim Enhanced Surface Water Treatment Rule, 2920=Carbon, Total
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in Las Vegas (City Of) Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify NM3518025's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NM3518025
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest New Mexico Community System Peers?

Compare four other New Mexico utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in New Mexico for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Lake Section Water Company (NM3529207) Chaparral 14,619 Groundwater 0
Mescalero Inn Of The Mt. Gods (063506008) New Mexico 14,542 Groundwater 0
Silver City Water System (NM3522609) Silver City 14,400 Groundwater 0
Portales Water System (NM3528522) Portales 14,284 Groundwater 0

When Should Las Vegas (City Of) Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Las Vegas; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: NM3518025

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Las Vegas (City Of)'s supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Las Vegas (City Of) (NM3518025) as a Surface Water community system serving 14,530 residents across San Miguel. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Should Las Vegas (City Of) homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 66 laboratory tests for Las Vegas (City Of) reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Does EPA's 10 ppb LCRI lead rule apply to houses on Las Vegas (City Of)?

Across the 1 ZIP codes served by Las Vegas (City Of), approximately 60.8% of residential housing units were built before 1980 (35.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks