Skip to main content
Safe drinking water record · NY3730165

Richland Town Pws Water Quality, PFAS & Utility Report (NY3730165)

Operating under Local Government management in Richland (T), New York, Richland Town Pws (NY3730165) serves 3,950 residents via ground water. Federal screening logs show zero 3-year EPA health or monitoring rule violations on record, all 120 federal UCMR 5 PFAS lab runs tested non-detect, making standard sediment pre-filter + nsf 53 lead check the primary home filtration takeaway.

EPA PWSID
NY3730165
Population Served
3,950
Water Source
Groundwater
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Local water quality & plumbing fit

Because Richland Town Pws relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; New York's statewide USGS median is 1.4 GPG (Soft). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 7,598 housing units in Richland Town Pws's 3 ZIP codes (median value $137,133), 60.0% predates 1980 (36.9% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Should Richland (T) Homeowners Know About Richland Town Pws?

Key federal SDWIS metrics for NY3730165 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Richland Town Pws (NY3730165)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership NY3730165 (Local Government) Active CWS Last sanitary visit: 10/07/2025
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 3,950 residents #277 in New York Counties: Oswego
Served ZIP Codes 13114, 13142, 13144 3 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 60.0% (36.9% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 1.4 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

What Does UCMR 5 Testing Reveal About NY3730165?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Richland Town Pws in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NY3730165
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Where Can You Compare Richland Town Pws With Other New York Systems?

Four peer New York utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in New York for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Saratoga Springs City (Geyser Crest) (NY4500178) Saratoga Sprngs (C) 4,000 Groundwater 0
Highland Water District (NY5503368) Lloyd (T) 4,000 Surface / Mixed 0
South Glens Falls Village (NY4500170) South Glens Falls (V) 3,900 Surface / Mixed 0
Liberty Village (NY5203329) Liberty (V) 3,900 Surface / Mixed 0

When Should Richland Town Pws Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Richland (T); interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.4 GPG) and add scale inhibition on groundwater feeds.

Common Questions for Richland Town Pws Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is tap water from Richland Town Pws surface-treated or well-sourced?

EPA ECHO classifies Richland Town Pws (NY3730165) as a Ground Water community system serving 3,950 residents across Oswego. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Did Richland Town Pws exceed EPA's 4.0 ppt PFOA or PFOS standard?

Federal UCMR 5 sampling covering 120 laboratory tests for Richland Town Pws reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Are pre-1980 copper solder or galvanized lines common in Richland Town Pws's ZIP codes?

Across the 3 ZIP codes served by Richland Town Pws, approximately 60.0% of residential housing units were built before 1980 (36.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks