Skip to main content
Safe drinking water record · NY5304410

Waverly Village Water Quality, PFAS & Utility Report (NY5304410)

Operating under Local Government management in Barton (T), New York, Waverly Village (NY5304410) serves 4,830 residents via ground water. Federal screening logs show zero EPA health violations alongside 1 monitoring/reporting notice, UCMR 5 samples measured 5.4 ppt for PFOA (exceeding the 4.0 ppt federal rule), making install nsf 58 under-sink ro or nsf 53 pfas carbon the primary home filtration takeaway.

EPA PWSID
NY5304410
Population Served
4,830
Water Source
Groundwater
Max UCMR 5 PFAS
5.4 ppt (PFOA)
3-Yr Health Flags
0 Health Viol.
Local water quality & plumbing fit

Because Waverly Village relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; New York's statewide USGS median is 1.4 GPG (Soft). UCMR 5 samples reached 5.4 ppt for PFOA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 3,887 housing units in Waverly Village's 1 ZIP code (median value $139,500), 67.2% predates 1980 (46.4% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Should Barton (T) Homeowners Know About Waverly Village?

Key federal SDWIS metrics for NY5304410 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Waverly Village (NY5304410)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership NY5304410 (Local Government) Active CWS Last sanitary visit: 06/30/2025
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 4,830 residents #248 in New York Counties: Tioga
Served ZIP Codes 14892 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 67.2% (46.4% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 1 rule violation (2 qtrs) Zero health flags target 2456=Total Haloacetic Acids (Haa5), 2950=Tthm
State Tap Hardness Baseline 1.4 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

What Does UCMR 5 Testing Reveal About NY5304410?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Waverly Village in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NY5304410
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 5.4 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Where Can You Compare Waverly Village With Other New York Systems?

Four peer New York utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in New York for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Hoosick Falls (V) Pws (NY4100041) Hoosick Falls (V) 4,925 Groundwater 0
Veolia Of Owego (NY5304409) Owego (V) 4,850 Groundwater 0
Old Westbury (V) (NY2902843) Old Westbury (V) 4,700 Groundwater 0
Heritage Hills Water System (NY5917221) Somers (T) 4,700 Groundwater 0

When Should Waverly Village Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Barton (T); interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.4 GPG) and add scale inhibition on groundwater feeds.

Common Questions for Waverly Village Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is tap water from Waverly Village surface-treated or well-sourced?

EPA ECHO classifies Waverly Village (NY5304410) as a Ground Water community system serving 4,830 residents across Tioga. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Did Waverly Village exceed EPA's 4.0 ppt PFOA or PFOS standard?

Yes—UCMR 5 laboratory testing for NY5304410 recorded 4 PFAS detections peaking at 5.4 ppt (PFOA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Are pre-1980 copper solder or galvanized lines common in Waverly Village's ZIP codes?

Across the 1 ZIP codes served by Waverly Village, approximately 67.2% of residential housing units were built before 1980 (46.4% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks