Skip to main content
Community water audit · NC0156025 in NC

Old Fort, Town Of Water Quality, PFAS & Utility Report (NC0156025)

Homeowners connected to Old Fort, Town Of (NC0156025) in Old Fort, North Carolina receive ground water across a 1,700-person distribution network. EPA SDWIS records document zero EPA health violations alongside 2 monitoring/reporting notices; under UCMR 5 monitoring, UCMR 5 samples measured 5.1 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 52.6% of homes across 1 served ZIP code predate 1980.

EPA PWSID
NC0156025
Population Served
1,700
Water Source
Groundwater
Max UCMR 5 PFAS
5.1 ppt (PFBS)
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Old Fort, Town Of

Because Old Fort, Town Of relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; North Carolina's statewide USGS median is 1.7 GPG (Soft). UCMR 5 samples reached 5.1 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 3,544 housing units in Old Fort, Town Of's 1 ZIP code (median value $176,300), 52.6% predates 1980 (25.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Old Fort, Town Of?

Examine Old Fort, Town Of's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Mcdowell.

EPA SDWA and local housing profile for Old Fort, Town Of (NC0156025)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership NC0156025 (Local Government) Active CWS Last sanitary visit: 08/29/2024
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 1,700 residents #283 in North Carolina Counties: Mcdowell
Served ZIP Codes 28762 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 52.6% (25.3% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 2 rule violations (4 qtrs) Zero health flags target 5000=Lead And Copper Rule
State Tap Hardness Baseline 1.7 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in Old Fort, Town Of Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify NC0156025's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NC0156025
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest North Carolina Community System Peers?

Compare four other North Carolina utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in North Carolina for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Lamplighter South-Danby (NC0160156) Charlotte 3,297 Surface / Mixed 0
Grifton, Town Of (NC0474035) Grifton 2,982 Surface / Mixed 0
Littleton, Town Of (NC0442028) Littleton 1,540 Surface / Mixed 0
Diamond Head S/D (NC0149182) Mooresville 1,433 Groundwater 0

When Should Old Fort, Town Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Old Fort; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.7 GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: NC0156025

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Old Fort, Town Of's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Old Fort, Town Of (NC0156025) as a Ground Water community system serving 1,700 residents across Mcdowell. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Should Old Fort, Town Of homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for NC0156025 recorded 1 PFAS detections peaking at 5.1 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Does EPA's 10 ppb LCRI lead rule apply to houses on Old Fort, Town Of?

Across the 1 ZIP codes served by Old Fort, Town Of, approximately 52.6% of residential housing units were built before 1980 (25.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks