Skip to main content
EPA SDWA profile · NC0291010 (North Carolina)

Henderson-Kerr Lake Reg Wtr Water Quality, PFAS & Utility Report (NC0291010)

Ranked #106 of 290 major community water utilities in North Carolina, Henderson-Kerr Lake Reg Wtr (NC0291010) delivers surface water to 14,937 people around Henderson. Public records indicate zero EPA health violations alongside 2 monitoring/reporting notices and note that UCMR 5 samples measured 4.8 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

EPA PWSID
NC0291010
Population Served
14,937
Water Source
Surface Water
Max UCMR 5 PFAS
4.8 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Homeowner takeaway for NC0291010

Drawing surface water across Henderson, Henderson-Kerr Lake Reg Wtr uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 4.8 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 7,432 housing units in Henderson-Kerr Lake Reg Wtr's 1 ZIP code (median value $120,600), 71.6% predates 1980 (33.0% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

Which Compliance and Housing Indicators Define NC0291010?

These verified utility measurements pair EPA SDWIS facility data for Henderson-Kerr Lake Reg Wtr with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Henderson-Kerr Lake Reg Wtr (NC0291010)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership NC0291010 (Local Government) Active CWS Last sanitary visit: 06/09/2026
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 14,937 residents #106 in North Carolina Counties: Vance
Served ZIP Codes 27536 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 71.6% (33.0% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 2 rule violations (3 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 1.7 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

How Do Henderson-Kerr Lake Reg Wtr PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Henderson-Kerr Lake Reg Wtr's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NC0291010
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS 4.8 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

What Do Neighboring Community Water Systems Report in North Carolina?

Cross-check four peer North Carolina water utilities to see how Henderson-Kerr Lake Reg Wtr ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in North Carolina for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Cliffdale West (NC0326332) Fayetteville 15,220 Groundwater 0
Reidsville, City Of (NC0279020) Reidsville 15,000 Surface / Mixed 0
Havelock Water System (NC0425015) Havelock 14,925 Groundwater 0
Kings Mountain, Town Of (NC0123020) Kings Mountain 14,784 Surface / Mixed 0

When Should Henderson-Kerr Lake Reg Wtr Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Henderson; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.7 GPG) and add scale inhibition on groundwater feeds.

Key Questions About Tap Water From Henderson-Kerr Lake Reg Wtr

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What water source serves the 14,937 customers under EPA ID NC0291010?

EPA ECHO classifies Henderson-Kerr Lake Reg Wtr (NC0291010) as a Surface Water community system serving 14,937 residents across Vance. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

How do Henderson-Kerr Lake Reg Wtr PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for NC0291010 recorded 2 PFAS detections peaking at 4.8 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

What pipe materials should homeowners served by Henderson-Kerr Lake Reg Wtr inspect?

Across the 1 ZIP codes served by Henderson-Kerr Lake Reg Wtr, approximately 71.6% of residential housing units were built before 1980 (33.0% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks