Skip to main content
EPA SDWA profile · OH2101412 (Ohio)

Del-Co Water Company, Inc. Water Quality, PFAS & Utility Report (OH2101412)

Ranked #7 of 319 major community water utilities in Ohio, Del-Co Water Company, Inc. (OH2101412) delivers surface water to 150,000 people around Delaware. Public records indicate zero 3-year EPA health or monitoring rule violations on record and note that UCMR 5 samples measured 4.3 ppt for PFBS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 RO + whole-house pre-filter.

EPA PWSID
OH2101412
Population Served
150,000
Water Source
Surface Water
Max UCMR 5 PFAS
4.3 ppt (PFBS)
3-Yr Health Flags
0 Health Viol.
Homeowner takeaway for OH2101412

Drawing surface water across Delaware, Del-Co Water Company, Inc. uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 4.3 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 321,144 housing units in Del-Co Water Company, Inc.'s 39 ZIP codes (median value $290,962), 41.4% predates 1980 (21.0% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

Which Compliance and Housing Indicators Define OH2101412?

These verified utility measurements pair EPA SDWIS facility data for Del-Co Water Company, Inc. with Census housing vintage across its 39 served ZIP codes.

EPA SDWA and local housing profile for Del-Co Water Company, Inc. (OH2101412)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership OH2101412 (Private) Active CWS Last sanitary visit: 04/17/2024
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 150,000 residents #7 in Ohio Counties: Delaware
Served ZIP Codes 40233, 43003, 43011, 43015, 43016, 43017, 43019, 43021 (+31 more) 39 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 41.4% (21.0% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 15.6 GPG (Very Hard) >= 7.0 GPG = Hard Size ion-exchange resin on local grain test

How Do Del-Co Water Company, Inc. PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Del-Co Water Company, Inc.'s monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for OH2101412
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 4.2 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

What Do Neighboring Community Water Systems Report in Ohio?

Cross-check four peer Ohio water utilities to see how Del-Co Water Company, Inc. ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Ohio for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Akron City Pws (OH7700011) Summit 280,000 Surface / Mixed 0
Montgomery County Water Services 1 Pws (OH5701315) Montgomery 150,207 Surface / Mixed 0
Dayton Public Water System (OH5703512) Montgomery 141,407 Surface / Mixed 0
Clermont Public Water System (OH1302212) Clermont 133,059 Surface / Mixed 0

When Should Del-Co Water Company, Inc. Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Delaware; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (15.6 GPG) and add scale inhibition on groundwater feeds.

Key Questions About Tap Water From Del-Co Water Company, Inc.

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What water source serves the 150,000 customers under EPA ID OH2101412?

EPA ECHO classifies Del-Co Water Company, Inc. (OH2101412) as a Surface Water community system serving 150,000 residents across Delaware. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

How do Del-Co Water Company, Inc. PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for OH2101412 recorded 5 PFAS detections peaking at 4.3 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

What pipe materials should homeowners served by Del-Co Water Company, Inc. inspect?

Across the 35 ZIP codes served by Del-Co Water Company, Inc., approximately 41.4% of residential housing units were built before 1980 (21.0% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks