Napoleon City Water Quality, PFAS & Utility Report (OH3500811)

Homeowners connected to Napoleon City (OH3500811) in Henry, Ohio receive surface water across a 8,858-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, UCMR 5 samples measured 3.6 ppt for PFBS (under the 4.0 ppt federal rule), and 67.4% of homes across 4 served ZIP codes predate 1980.

EPA PWSID
OH3500811
Population Served
8,858
Water Source
Surface Water
Max UCMR 5 PFAS
3.6 ppt (PFBS)
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Napoleon City

Drawing surface water across Henry, Napoleon City uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Detectable trace PFBS (3.6 ppt) remains below EPA's 4.0 ppt enforcement ceiling, while activated carbon drinking filters reliably lower residual exposure.

Across 8,874 housing units in Napoleon City's 4 ZIP codes (median value $172,900), 67.4% predates 1980 (45.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Napoleon City?

Examine Napoleon City's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Henry.

EPA SDWA and local housing profile for Napoleon City (OH3500811)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership OH3500811 (Local Government) Active CWS Last sanitary visit: 10/18/2024
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 8,858 residents #178 in Ohio Counties: Henry
Served ZIP Codes 43532, 43534, 43535, 43545 4 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 67.4% (45.1% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 15.6 GPG (Very Hard) >= 7.0 GPG = Hard Size ion-exchange resin on local grain test

Are Forever Chemicals Detected in Napoleon City Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify OH3500811's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for OH3500811
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest Ohio Community System Peers?

Compare four other Ohio utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Ohio for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Clark County Northridge Pws (OH1201003) Clark 8,874 Groundwater 0
Scioto Water Inc.-Rose Hill (OH7300303) Scioto 8,861 Groundwater 0
Bryan City Pws (OH8600012) Williams 8,729 Groundwater 0
Portage County Water Resources (OH6702812) Portage 8,606 Groundwater 0

When Should Napoleon City Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Henry; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (15.6 GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: OH3500811

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Napoleon City's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Napoleon City (OH3500811) as a Surface Water community system serving 8,858 residents across Henry. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Should Napoleon City homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for OH3500811 recorded 1 PFAS detections peaking at 3.6 ppt (PFBS), which sits below EPA's 4.0 ppt federal MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Does EPA's 10 ppb LCRI lead rule apply to houses on Napoleon City?

Across the 4 ZIP codes served by Napoleon City, approximately 67.4% of residential housing units were built before 1980 (45.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks