Skip to main content
EPA SDWA profile · PA1090063 (Pennsylvania)

Upper Southampton Mun Auth Water Quality, PFAS & Utility Report (PA1090063)

Ranked #106 of 339 major community water utilities in Pennsylvania, Upper Southampton Mun Auth (PA1090063) delivers surface water purchased to 16,000 people around Bucks. Public records indicate zero EPA health violations alongside 3 monitoring/reporting notices and note that UCMR 5 samples measured 16.4 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

EPA PWSID
PA1090063
Population Served
16,000
Water Source
Surface Water
Max UCMR 5 PFAS
16.4 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Homeowner takeaway for PA1090063

Drawing surface water across Bucks, Upper Southampton Mun Auth uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 16.4 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 14,199 housing units in Upper Southampton Mun Auth's 1 ZIP code (median value $466,900), 62.1% predates 1980 (21.9% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

Which Compliance and Housing Indicators Define PA1090063?

These verified utility measurements pair EPA SDWIS facility data for Upper Southampton Mun Auth with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Upper Southampton Mun Auth (PA1090063)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership PA1090063 (Local Government) Active CWS Last sanitary visit: 08/21/2025
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 16,000 residents #106 in Pennsylvania Counties: Bucks
Served ZIP Codes 18966 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 62.1% (21.9% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 3 rule violations (9 qtrs) Zero health flags target 0700=Groundwater Rule, 4006=Combined Uranium
State Tap Hardness Baseline 4.8 GPG (Moderately Hard) >= 7.0 GPG = Hard Moderate mineral profile

How Do Upper Southampton Mun Auth PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Upper Southampton Mun Auth's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA1090063
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 14.2 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 16.4 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS 5.0 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

What Do Neighboring Community Water Systems Report in Pennsylvania?

Cross-check four peer Pennsylvania water utilities to see how Upper Southampton Mun Auth ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Pennsylvania for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Phoenixville Water Dept (PA1150077) Chester 16,599 Surface / Mixed 0
Robinson Twp Muni Auth (PA5020045) Allegheny 16,354 Surface / Mixed 0
Highridge Water Auth (PA5650069) Westmoreland 16,000 Surface / Mixed 0
Red Lion Municipal Authority (PA7670086) York 15,882 Surface / Mixed 0

When Should Upper Southampton Mun Auth Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Bucks; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

Key Questions About Tap Water From Upper Southampton Mun Auth

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What water source serves the 16,000 customers under EPA ID PA1090063?

EPA ECHO classifies Upper Southampton Mun Auth (PA1090063) as a Surface Water Purchased community system serving 16,000 residents across Bucks. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

How do Upper Southampton Mun Auth PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for PA1090063 recorded 16 PFAS detections peaking at 16.4 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

What pipe materials should homeowners served by Upper Southampton Mun Auth inspect?

Across the 1 ZIP codes served by Upper Southampton Mun Auth, approximately 62.1% of residential housing units were built before 1980 (21.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks