Skip to main content
Safe drinking water record · PA1460055

Pa American Audubon Water Quality, PFAS & Utility Report (PA1460055)

Operating under Private management in Montgomery, Pennsylvania, Pa American Audubon (PA1460055) serves 8,200 residents via surface water purchased. Federal screening logs show zero EPA health violations alongside 8 monitoring/reporting notices, UCMR 5 samples measured 57.9 ppt for PFOS (exceeding the 4.0 ppt federal rule), making install nsf 58 under-sink ro or nsf 53 pfas carbon the primary home filtration takeaway.

EPA PWSID
PA1460055
Population Served
8,200
Water Source
Surface Water
Max UCMR 5 PFAS
57.9 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Local water quality & plumbing fit

Drawing surface water across Montgomery, Pa American Audubon uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 57.9 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 19,720 housing units in Pa American Audubon's 2 ZIP codes (median value $355,700), 56.0% predates 1980 (25.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Should Montgomery Homeowners Know About Pa American Audubon?

Key federal SDWIS metrics for PA1460055 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Pa American Audubon (PA1460055)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership PA1460055 (Private) Active CWS Last sanitary visit: 10/10/2025
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 8,200 residents #182 in Pennsylvania Counties: Montgomery
Served ZIP Codes 19403, 19407 2 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 56.0% (25.6% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 8 rule violations (8 qtrs) Zero health flags target 0700=Groundwater Rule, 1040=Nitrate, 1041=Nitrite, 2005=Endrin
State Tap Hardness Baseline 4.8 GPG (Moderately Hard) >= 7.0 GPG = Hard Moderate mineral profile

What Does UCMR 5 Testing Reveal About PA1460055?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Pa American Audubon in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA1460055
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 30.8 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 57.9 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS 5.0 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
PFNA 6.6 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Where Can You Compare Pa American Audubon With Other Pennsylvania Systems?

Four peer Pennsylvania utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in Pennsylvania for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Hemlock Farms (Main) (PA2520033) Pike 8,321 Groundwater 0
Wellsboro Municipal Authority (PA2590042) Tioga 8,225 Surface / Mixed 0
Aqua Pa Spring Run (PA1150089) Chester 8,151 Surface / Mixed 0
Boyertown Muni Auth (PA3060081) Berks 8,000 Surface / Mixed 0

When Should Pa American Audubon Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Montgomery; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

Common Questions for Pa American Audubon Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is tap water from Pa American Audubon surface-treated or well-sourced?

EPA ECHO classifies Pa American Audubon (PA1460055) as a Surface Water Purchased community system serving 8,200 residents across Montgomery. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Did Pa American Audubon exceed EPA's 4.0 ppt PFOA or PFOS standard?

Yes—UCMR 5 laboratory testing for PA1460055 recorded 45 PFAS detections peaking at 57.9 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Are pre-1980 copper solder or galvanized lines common in Pa American Audubon's ZIP codes?

Across the 1 ZIP codes served by Pa American Audubon, approximately 56.0% of residential housing units were built before 1980 (25.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks