Skip to main content
Pennsylvania water passport · EPA PA7360058

City Of Lancaster Water Quality, PFAS & Utility Report (PA7360058)

City Of Lancaster (PA7360058) is a Local Government public water utility serving 120,000 residents in Lancaster, Pennsylvania primarily from surface water. EPA ECHO logs show zero EPA health violations alongside 2 monitoring/reporting notices, while UCMR 5 samples measured 23.8 ppt for PFOA (exceeding the 4.0 ppt federal rule). Roughly 56.0% of homes across 14 served ZIP codes predate 1980.

EPA PWSID
PA7360058
Population Served
120,000
Water Source
Surface Water
Max UCMR 5 PFAS
23.8 ppt (PFOA)
3-Yr Health Flags
0 Health Viol.
Filtration & pipe verdict for City Of Lancaster

Drawing surface water across Lancaster, City Of Lancaster uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 23.8 ppt for PFOA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 127,305 housing units in City Of Lancaster's 14 ZIP codes (median value $286,200), 56.0% predates 1980 (35.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Are City Of Lancaster's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in City Of Lancaster's network.

EPA SDWA and local housing profile for City Of Lancaster (PA7360058)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership PA7360058 (Local Government) Active CWS Last sanitary visit: 04/15/2025
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 120,000 residents #13 in Pennsylvania Counties: Lancaster
Served ZIP Codes 17505, 17512, 17520, 17540, 17543, 17545, 17551, 17554 (+6 more) 14 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 56.0% (35.6% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 2 rule violations (3 qtrs) Zero health flags target 0200=Surface Water Treatment Rule, 2950=Tthm
State Tap Hardness Baseline 4.8 GPG (Moderately Hard) >= 7.0 GPG = Hard Moderate mineral profile

Did PA7360058 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for City Of Lancaster against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA7360058
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 23.8 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

How Does City Of Lancaster Compare to Peer Pennsylvania Utilities?

Review four nearby Pennsylvania community water utilities matched by service rank inside Pennsylvania's 339-utility public water catalog.

Nearby community water systems in Pennsylvania for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Mawc Yough Plant (PA5260036) Fayette 133,000 Surface / Mixed 0
Wilkinsburg-Penn Jt Water Auth (PA5020056) Allegheny 125,000 Surface / Mixed 0
Lca Allentown Division (PA3390024) Lehigh 118,000 Surface / Mixed 0
City Of Bethlehem (PA3480046) Northampton 117,259 Surface / Mixed 0

When Should City Of Lancaster Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Lancaster; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

Homeowner Water Quality FAQs for City Of Lancaster (PA7360058)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Where does City Of Lancaster (PA7360058) source drinking water?

EPA ECHO classifies City Of Lancaster (PA7360058) as a Surface Water community system serving 120,000 residents across Lancaster. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Were PFAS compounds detected in City Of Lancaster UCMR 5 testing?

Yes—UCMR 5 laboratory testing for PA7360058 recorded 8 PFAS detections peaking at 23.8 ppt (PFOA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Could homes served by City Of Lancaster still face lead solder or older pipe risks?

Across the 14 ZIP codes served by City Of Lancaster, approximately 56.0% of residential housing units were built before 1980 (35.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks