Skip to main content
Pennsylvania water passport · EPA PA7360063

East Hempfield Water Auth Water Quality, PFAS & Utility Report (PA7360063)

East Hempfield Water Auth (PA7360063) is a Local Government public water utility serving 20,988 residents in Lancaster, Pennsylvania primarily from surface water purchased. EPA ECHO logs show zero EPA health violations alongside 2 monitoring/reporting notices, while UCMR 5 samples measured 9.0 ppt for PFOA (exceeding the 4.0 ppt federal rule). Roughly 60.8% of homes across 5 served ZIP codes predate 1980.

EPA PWSID
PA7360063
Population Served
20,988
Water Source
Surface Water
Max UCMR 5 PFAS
9.0 ppt (PFOA)
3-Yr Health Flags
0 Health Viol.
Filtration & pipe verdict for East Hempfield Water Auth

Drawing surface water across Lancaster, East Hempfield Water Auth uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 9.0 ppt for PFOA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 73,851 housing units in East Hempfield Water Auth's 5 ZIP codes (median value $278,050), 60.8% predates 1980 (39.5% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Are East Hempfield Water Auth's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in East Hempfield Water Auth's network.

EPA SDWA and local housing profile for East Hempfield Water Auth (PA7360063)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership PA7360063 (Local Government) Active CWS Last sanitary visit: 02/09/2026
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 20,988 residents #90 in Pennsylvania Counties: Lancaster
Served ZIP Codes 17538, 17601, 17602, 17603, 17604 5 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 60.8% (39.5% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 2 rule violations (2 qtrs) Zero health flags target 1040=Nitrate
State Tap Hardness Baseline 4.8 GPG (Moderately Hard) >= 7.0 GPG = Hard Moderate mineral profile

Did PA7360063 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for East Hempfield Water Auth against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA7360063
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 9.0 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 5.0 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

How Does East Hempfield Water Auth Compare to Peer Pennsylvania Utilities?

Review four nearby Pennsylvania community water utilities matched by service rank inside Pennsylvania's 339-utility public water catalog.

Nearby community water systems in Pennsylvania for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Nwwa Warrington Township (PA1090070) Bucks 21,588 Surface / Mixed 0
Dover Twp Water Sys (PA7670073) York 21,097 Surface / Mixed 0
Paw Philipsburg (PA4140087) Centre 20,865 Surface / Mixed 0
Ambler Boro Water Dept (PA1460020) Montgomery 20,000 Surface / Mixed 0

When Should East Hempfield Water Auth Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Lancaster; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

Homeowner Water Quality FAQs for East Hempfield Water Auth (PA7360063)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Where does East Hempfield Water Auth (PA7360063) source drinking water?

EPA ECHO classifies East Hempfield Water Auth (PA7360063) as a Surface Water Purchased community system serving 20,988 residents across Lancaster. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Were PFAS compounds detected in East Hempfield Water Auth UCMR 5 testing?

Yes—UCMR 5 laboratory testing for PA7360063 recorded 10 PFAS detections peaking at 9.0 ppt (PFOA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Could homes served by East Hempfield Water Auth still face lead solder or older pipe risks?

Across the 4 ZIP codes served by East Hempfield Water Auth, approximately 60.8% of residential housing units were built before 1980 (39.5% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks