Skip to main content
Safe drinking water record · TX0040002

City Of Rockport Water Quality, PFAS & Utility Report (TX0040002)

Operating under Local Government management in Aransas, Texas, City Of Rockport (TX0040002) serves 11,186 residents via surface water purchased. Federal screening logs show zero EPA health violations alongside 1 monitoring/reporting notice, all 240 federal UCMR 5 PFAS lab runs tested non-detect, making kitchen nsf 53 catalytic carbon filter the primary home filtration takeaway.

EPA PWSID
TX0040002
Population Served
11,186
Water Source
Surface Water
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Local water quality & plumbing fit

Drawing surface water across Aransas, City Of Rockport uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 13,048 housing units in City Of Rockport's 1 ZIP code (median value $238,200), 30.8% predates 1980 (7.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Should Aransas Homeowners Know About City Of Rockport?

Key federal SDWIS metrics for TX0040002 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for City Of Rockport (TX0040002)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership TX0040002 (Local Government) Active CWS Last sanitary visit: 09/27/2024
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 11,186 residents #371 in Texas Counties: Aransas
Served ZIP Codes 78382 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 30.8% (7.6% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 1 rule violation (4 qtrs) Zero health flags target 5200=Lead And Copper Rule Revisions
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

What Does UCMR 5 Testing Reveal About TX0040002?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for City Of Rockport in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for TX0040002
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Where Can You Compare City Of Rockport With Other Texas Systems?

Four peer Texas utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in Texas for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Harris County Ud 6 (TX1010501) Harris 11,262 Surface / Mixed 0
City Of La Grulla (TX2140006) Starr 11,250 Surface / Mixed 7
Gastonia Scurry Sud (TX1290015) Kaufman 11,169 Surface / Mixed 0
North Austin Mud 1 (TX2270226) Travis 11,133 Surface / Mixed 0

When Should City Of Rockport Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Aransas; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Common Questions for City Of Rockport Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is tap water from City Of Rockport surface-treated or well-sourced?

EPA ECHO classifies City Of Rockport (TX0040002) as a Surface Water Purchased community system serving 11,186 residents across Aransas. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Did City Of Rockport exceed EPA's 4.0 ppt PFOA or PFOS standard?

Federal UCMR 5 sampling covering 240 laboratory tests for City Of Rockport reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Are pre-1980 copper solder or galvanized lines common in City Of Rockport's ZIP codes?

Across the 1 ZIP codes served by City Of Rockport, approximately 30.8% of residential housing units were built before 1980 (7.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks