Skip to main content
Texas water passport ยท EPA TX1130031

The Consolidated Wsc Central System Water Quality, PFAS & Utility Report (TX1130031)

The Consolidated Wsc Central System (TX1130031) is a Local Government public water utility serving 3,878 residents in Houston, Texas primarily from ground water. EPA ECHO logs show zero EPA health violations alongside 6 monitoring/reporting notices, while all 180 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 49.7% of homes across 4 served ZIP codes predate 1980.

EPA PWSID
TX1130031
Population Served
3,878
Water Source
Groundwater
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Filtration & pipe verdict for The Consolidated Wsc Central System

Drawing surface water across Houston, The Consolidated Wsc Central System uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 10,283 housing units in The Consolidated Wsc Central System's 4 ZIP codes (median value $138,825), 49.7% predates 1980 (18.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Are The Consolidated Wsc Central System's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in The Consolidated Wsc Central System's network.

EPA SDWA and local housing profile for The Consolidated Wsc Central System (TX1130031)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership TX1130031 (Local Government) Active CWS Last sanitary visit: 05/24/2024
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 3,878 residents #1,036 in Texas Counties: Houston
Served ZIP Codes 75835, 75844, 75849, 75851 4 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 49.7% (18.6% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 6 rule violations (12 qtrs) Zero health flags target 1040=Nitrate, 2456=Total Haloacetic Acids (Haa5), 2950=Tthm, 5000=Lead And Copper Rule
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

Did TX1130031 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for The Consolidated Wsc Central System against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for TX1130031
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

How Does The Consolidated Wsc Central System Compare to Peer Texas Utilities?

Review four nearby Texas community water utilities matched by service rank inside Texas's 1,193-utility public water catalog.

Nearby community water systems in Texas for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Gholson Wsc (TX1550028) Mclennan 3,903 Groundwater 0
Harris County Mud 173 (TX1012971) Harris 3,894 Surface / Mixed 0
Bella Vista (TX1460175) Liberty 3,876 Groundwater 0
Lindale Rural Wsc Dc (TX2120011) Smith 3,876 Groundwater 0

When Should The Consolidated Wsc Central System Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Houston; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Homeowner Water Quality FAQs for The Consolidated Wsc Central System (TX1130031)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Where does The Consolidated Wsc Central System (TX1130031) source drinking water?

EPA ECHO classifies The Consolidated Wsc Central System (TX1130031) as a Ground Water community system serving 3,878 residents across Houston. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Were PFAS compounds detected in The Consolidated Wsc Central System UCMR 5 testing?

Federal UCMR 5 sampling covering 180 laboratory tests for The Consolidated Wsc Central System reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Could homes served by The Consolidated Wsc Central System still face lead solder or older pipe risks?

Across the 4 ZIP codes served by The Consolidated Wsc Central System, approximately 49.7% of residential housing units were built before 1980 (18.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019โ€“2023 5-Year Summary File — U.S. Census Bureau, 2019โ€“2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks