Skip to main content
Community water audit · TX1780017 in TX

Naval Air Station Corpus Christi Water Quality, PFAS & Utility Report (TX1780017)

Homeowners connected to Naval Air Station Corpus Christi (TX1780017) in Nueces, Texas receive surface water purchased across a 7,048-person distribution network. EPA SDWIS records document zero EPA health violations alongside 1 monitoring/reporting notice; under UCMR 5 monitoring, all 120 federal UCMR 5 PFAS lab runs tested non-detect, and 12.0% of homes across 1 served ZIP code predate 1980.

EPA PWSID
TX1780017
Population Served
7,048
Water Source
Surface Water
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Naval Air Station Corpus Christi

Drawing surface water across Nueces, Naval Air Station Corpus Christi uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Even when Naval Air Station Corpus Christi passes distribution sampling, interior plumbing installed before June 1986 can contribute brass or lead solder leachate after overnight stagnation—flushing cold kitchen lines for 30–60 seconds cuts first-draw spikes.

How Clean and Hard Is Tap Water Supplied by Naval Air Station Corpus Christi?

Examine Naval Air Station Corpus Christi's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Nueces.

EPA SDWA and local housing profile for Naval Air Station Corpus Christi (TX1780017)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership TX1780017 (Federal Government) Active CWS Last sanitary visit: 05/28/2024
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 7,048 residents #604 in Texas Counties: Nueces
Served ZIP Codes 78419 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 12.0% (2.3% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 1 rule violation (3 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in Naval Air Station Corpus Christi Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify TX1780017's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for TX1780017
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest Texas Community System Peers?

Compare four other Texas utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Texas for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Galveston County Wcid 8 (TX0840009) Galveston 7,065 Surface / Mixed 0
Plum Creek (TX1050028) Hays 7,065 Surface / Mixed 0
Harris County Mud 196 (TX1013002) Harris 7,026 Surface / Mixed 0
City Of Burnet (TX0270001) Burnet 7,011 Surface / Mixed 0

When Should Naval Air Station Corpus Christi Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Nueces; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: TX1780017

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Naval Air Station Corpus Christi's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Naval Air Station Corpus Christi (TX1780017) as a Surface Water Purchased community system serving 7,048 residents across Nueces. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Should Naval Air Station Corpus Christi homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 120 laboratory tests for Naval Air Station Corpus Christi reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Does EPA's 10 ppb LCRI lead rule apply to houses on Naval Air Station Corpus Christi?

Across the 1 ZIP codes served by Naval Air Station Corpus Christi, approximately 12.0% of residential housing units were built before 1980 (2.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks