Skip to main content
Community water audit · VA3093640 in VA

Smithfield, Town Of Water Quality, PFAS & Utility Report (VA3093640)

Homeowners connected to Smithfield, Town Of (VA3093640) in Isle Of Wight, Virginia receive ground water across a 8,089-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, all 240 federal UCMR 5 PFAS lab runs tested non-detect, and 35.4% of homes across 1 served ZIP code predate 1980.

EPA PWSID
VA3093640
Population Served
8,089
Water Source
Groundwater
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Smithfield, Town Of

Because Smithfield, Town Of relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Virginia's statewide USGS median is 1.9 GPG (Soft). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 7,961 housing units in Smithfield, Town Of's 1 ZIP code (median value $347,700), 35.4% predates 1980 (12.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Smithfield, Town Of?

Examine Smithfield, Town Of's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Isle Of Wight.

EPA SDWA and local housing profile for Smithfield, Town Of (VA3093640)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership VA3093640 (Local Government) Active CWS Last sanitary visit: 04/10/2026
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 8,089 residents #85 in Virginia Counties: Isle Of Wight
Served ZIP Codes 23430 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 35.4% (12.8% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 1.9 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in Smithfield, Town Of Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify VA3093640's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for VA3093640
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest Virginia Community System Peers?

Compare four other Virginia utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Virginia for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Greene County Water & Sewer (VA2079625) Greene 8,500 Surface / Mixed 0
Farmville, Town Of (VA5147170) Prince Edward 8,212 Surface / Mixed 0
Central Water System (VA4127190) New Kent 7,864 Groundwater 0
Verona - Weyers Cave (VA2015725) Augusta 7,808 Surface / Mixed 0

When Should Smithfield, Town Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Isle Of Wight; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.9 GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: VA3093640

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Smithfield, Town Of's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Smithfield, Town Of (VA3093640) as a Ground Water community system serving 8,089 residents across Isle Of Wight. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Should Smithfield, Town Of homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 240 laboratory tests for Smithfield, Town Of reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Does EPA's 10 ppb LCRI lead rule apply to houses on Smithfield, Town Of?

Across the 1 ZIP codes served by Smithfield, Town Of, approximately 35.4% of residential housing units were built before 1980 (12.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks