Skip to main content
Safe drinking water record · VA5031050

Altavista, Town Of Water Quality, PFAS & Utility Report (VA5031050)

Operating under Local Government management in Campbell, Virginia, Altavista, Town Of (VA5031050) serves 3,850 residents via surface water. Federal screening logs show zero 3-year EPA health or monitoring rule violations on record, UCMR 5 samples measured 6.2 ppt for HFPO-DA (exceeding the 4.0 ppt federal rule), making install nsf 58 under-sink ro or nsf 53 pfas carbon the primary home filtration takeaway.

EPA PWSID
VA5031050
Population Served
3,850
Water Source
Surface Water
Max UCMR 5 PFAS
6.2 ppt (HFPO-DA)
3-Yr Health Flags
0 Health Viol.
Local water quality & plumbing fit

Drawing surface water across Campbell, Altavista, Town Of uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 6.2 ppt for HFPO-DA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 5,029 housing units in Altavista, Town Of's 2 ZIP codes (median value $133,800), 66.7% predates 1980 (30.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Should Campbell Homeowners Know About Altavista, Town Of?

Key federal SDWIS metrics for VA5031050 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Altavista, Town Of (VA5031050)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership VA5031050 (Local Government) Active CWS Last sanitary visit: 12/06/2023
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 3,850 residents #143 in Virginia Counties: Campbell
Served ZIP Codes 24517, 24563 2 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 66.7% (30.8% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 1.9 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

What Does UCMR 5 Testing Reveal About VA5031050?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Altavista, Town Of in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for VA5031050
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA 6.2 ppt 10 ppt EPA MCL Detected below final EPA federal MCL

Where Can You Compare Altavista, Town Of With Other Virginia Systems?

Four peer Virginia utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in Virginia for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Colonial Beach, Town Of (VA4193280) Westmoreland 3,875 Groundwater 0
Baptist Valley (VA1185763) Tazewell 3,857 Surface / Mixed 0
Woodway Water Authority (VA1105900) Lee 3,800 Surface / Mixed 0
Christiansburg Elliston Waterline (VA1121175) Montgomery 3,626 Surface / Mixed 0

When Should Altavista, Town Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Campbell; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.9 GPG) and add scale inhibition on groundwater feeds.

Common Questions for Altavista, Town Of Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is tap water from Altavista, Town Of surface-treated or well-sourced?

EPA ECHO classifies Altavista, Town Of (VA5031050) as a Surface Water community system serving 3,850 residents across Campbell. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Did Altavista, Town Of exceed EPA's 4.0 ppt PFOA or PFOS standard?

Yes—UCMR 5 laboratory testing for VA5031050 recorded 1 PFAS detections peaking at 6.2 ppt (HFPO-DA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Are pre-1980 copper solder or galvanized lines common in Altavista, Town Of's ZIP codes?

Across the 2 ZIP codes served by Altavista, Town Of, approximately 66.7% of residential housing units were built before 1980 (30.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks