Skip to main content
Safe drinking water record · WA5360100

North Bend City Of Water Quality, PFAS & Utility Report (WA5360100)

Operating under Local Government management in King, Washington, North Bend City Of (WA5360100) serves 8,710 residents via ground water. Federal screening logs show zero EPA health violations alongside 1 monitoring/reporting notice, all 120 federal UCMR 5 PFAS lab runs tested non-detect, making standard sediment pre-filter + nsf 53 lead check the primary home filtration takeaway.

EPA PWSID
WA5360100
Population Served
8,710
Water Source
Groundwater
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Local water quality & plumbing fit

Because North Bend City Of relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Washington's statewide USGS median is 4.1 GPG (Moderately Hard). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 5,871 housing units in North Bend City Of's 1 ZIP code (median value $845,700), 31.9% predates 1980 (10.5% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Should King Homeowners Know About North Bend City Of?

Key federal SDWIS metrics for WA5360100 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for North Bend City Of (WA5360100)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership WA5360100 (Local Government) Active CWS Last sanitary visit: 09/14/2022
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 8,710 residents #145 in Washington Counties: King
Served ZIP Codes 98045 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 31.9% (10.5% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 1 rule violation (1 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 4.1 GPG (Moderately Hard) >= 7.0 GPG = Hard Moderate mineral profile

What Does UCMR 5 Testing Reveal About WA5360100?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for North Bend City Of in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for WA5360100
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Where Can You Compare North Bend City Of With Other Washington Systems?

Four peer Washington utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in Washington for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Union Hill Water Association Inc (WA5390260) King 8,720 Groundwater 0
Ephrata Water Department (WA5323650) Grant 8,718 Groundwater 0
Steilacoom Town Of (WA5384000) Pierce 8,545 Groundwater 0
Sultan Water Department (WA5384770) Snohomish 8,424 Surface / Mixed 0

When Should North Bend City Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in King; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (4.1 GPG) and add scale inhibition on groundwater feeds.

Common Questions for North Bend City Of Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is tap water from North Bend City Of surface-treated or well-sourced?

EPA ECHO classifies North Bend City Of (WA5360100) as a Ground Water community system serving 8,710 residents across King. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Did North Bend City Of exceed EPA's 4.0 ppt PFOA or PFOS standard?

Federal UCMR 5 sampling covering 120 laboratory tests for North Bend City Of reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Are pre-1980 copper solder or galvanized lines common in North Bend City Of's ZIP codes?

Across the 1 ZIP codes served by North Bend City Of, approximately 31.9% of residential housing units were built before 1980 (10.5% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks