Skip to main content
Community water audit · WV3300512 in WV

Follansbee Hooverson Heights Water Quality, PFAS & Utility Report (WV3300512)

Homeowners connected to Follansbee Hooverson Heights (WV3300512) in Follansbee, West Virginia receive surface water across a 4,970-person distribution network. EPA SDWIS records document zero EPA health violations alongside 2 monitoring/reporting notices; under UCMR 5 monitoring, UCMR 5 samples measured 3.3 ppt for PFBS (under the 4.0 ppt federal rule), and 74.5% of homes across 3 served ZIP codes predate 1980.

EPA PWSID
WV3300512
Population Served
4,970
Water Source
Surface Water
Max UCMR 5 PFAS
3.3 ppt (PFBS)
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Follansbee Hooverson Heights

Drawing surface water across Follansbee, Follansbee Hooverson Heights uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Detectable trace PFBS (3.3 ppt) remains below EPA's 4.0 ppt enforcement ceiling, while activated carbon drinking filters reliably lower residual exposure.

Across 7,909 housing units in Follansbee Hooverson Heights's 3 ZIP codes (median value $136,067), 74.5% predates 1980 (43.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Follansbee Hooverson Heights?

Examine Follansbee Hooverson Heights's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Brooke.

EPA SDWA and local housing profile for Follansbee Hooverson Heights (WV3300512)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership WV3300512 (Local Government) Active CWS Last sanitary visit: 05/02/2023
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 4,970 residents #56 in West Virginia Counties: Brooke
Served ZIP Codes 26035, 26037, 26070 3 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 74.5% (43.8% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 2 rule violations (8 qtrs) Zero health flags target 2456=Total Haloacetic Acids (Haa5), 2950=Tthm
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in Follansbee Hooverson Heights Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify WV3300512's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for WV3300512
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest West Virginia Community System Peers?

Compare four other West Virginia utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in West Virginia for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Ravenswood Municipal Water Works (WV3301810) Ravenswood 5,047 Groundwater 8
Craigsville Psd (WV3303402) Craigsville 4,997 Surface / Mixed 0
Tomlinson Psd-Newell (WV3301516) Newell 4,963 Groundwater 2
Shinnston City Of (WV3301721) Shinnston 4,959 Surface / Mixed 9

When Should Follansbee Hooverson Heights Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Follansbee; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: WV3300512

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Follansbee Hooverson Heights's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Follansbee Hooverson Heights (WV3300512) as a Surface Water community system serving 4,970 residents across Brooke. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Should Follansbee Hooverson Heights homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for WV3300512 recorded 2 PFAS detections peaking at 3.3 ppt (PFBS), which sits below EPA's 4.0 ppt federal MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Does EPA's 10 ppb LCRI lead rule apply to houses on Follansbee Hooverson Heights?

Across the 3 ZIP codes served by Follansbee Hooverson Heights, approximately 74.5% of residential housing units were built before 1980 (43.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks