Skip to main content
West Virginia water passport ยท EPA WV3302104

Wvaw - Weston Water Quality, PFAS & Utility Report (WV3302104)

Wvaw - Weston (WV3302104) is a Private public water utility serving 14,534 residents in Weston, West Virginia primarily from surface water. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while all 120 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 68.7% of homes across 1 served ZIP code predate 1980.

EPA PWSID
WV3302104
Population Served
14,534
Water Source
Surface Water
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Filtration & pipe verdict for Wvaw - Weston

Drawing surface water across Weston, Wvaw - Weston uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 4,624 housing units in Wvaw - Weston's 1 ZIP code (median value $112,500), 68.7% predates 1980 (43.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Are Wvaw - Weston's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Wvaw - Weston's network.

EPA SDWA and local housing profile for Wvaw - Weston (WV3302104)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership WV3302104 (Private) Active CWS Last sanitary visit: 07/23/2024
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 14,534 residents #17 in West Virginia Counties: Lewis
Served ZIP Codes 26452 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 68.7% (43.3% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

Did WV3302104 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Wvaw - Weston against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for WV3302104
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

How Does Wvaw - Weston Compare to Peer West Virginia Utilities?

Review four nearby West Virginia community water utilities matched by service rank inside West Virginia's 98-utility public water catalog.

Nearby community water systems in West Virginia for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Martinsburg City Of (WV3300212) Martinsburg 16,250 Surface / Mixed 0
Charles Town Utilities (WV3301905) Charles Town 15,220 Surface / Mixed 0
St Albans Water (WV3302031) St. Albans 13,758 Surface / Mixed 0
Vienna (WV3305411) Vienna 12,507 Groundwater 0

When Should Wvaw - Weston Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Weston; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Homeowner Water Quality FAQs for Wvaw - Weston (WV3302104)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Where does Wvaw - Weston (WV3302104) source drinking water?

EPA ECHO classifies Wvaw - Weston (WV3302104) as a Surface Water community system serving 14,534 residents across Lewis. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Were PFAS compounds detected in Wvaw - Weston UCMR 5 testing?

Federal UCMR 5 sampling covering 120 laboratory tests for Wvaw - Weston reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Could homes served by Wvaw - Weston still face lead solder or older pipe risks?

Across the 1 ZIP codes served by Wvaw - Weston, approximately 68.7% of residential housing units were built before 1980 (43.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019โ€“2023 5-Year Summary File — U.S. Census Bureau, 2019โ€“2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks