A. O. Smith Water Heater Code 110 / 120 (Tankless): Meaning & Diagnostic Steps

Showing A. O. Smith Code 110 / 120 (Tankless) means Ignition or flame loss fault on A. O. Smith ATI/ProLine tankless on A. O. Smith / Takagi Condensing Tankless. Recommended service scope (Licensed Gas Plumber Required) focuses on Undersized 1/2 in. gas supply failing 199K BTU/h load; Blocked exhaust or condensate trap.

Fault / Blink Code
Code 110 / 120 (Tankless)
Control Platform
A. O. Smith / Takagi Condensing Tankless
Severity Class
Ignition / Gas Lockout
DIY vs. Pro Scope
Licensed Gas Plumber Required
Gas & Electrical Safety Protocol If you detect a rotten-egg gas odor or observe scorched wiring, shut off the manual gas valve/breaker immediately, ventilate or evacuate, and call 911. Do not open sealed gas combustion chambers without proper licensing.
Hand turning red quarter-turn brass main water shutoff valve on three-quarter-inch copper line
Hand turning red quarter-turn brass main water shutoff valve on three-quarter-inch copper line

What Causes A. O. Smith Code 110 / 120 (Tankless)?

A. O. Smith Code 110 / 120 (Tankless) triggers on A. O. Smith / Takagi Condensing Tankless controls when ignition or flame loss fault on a. o. smith ati/proline tankless. Review the primary root causes and field diagnostic checks below before ordering replacement gas or ignition parts.

  • Undersized 1/2 in. gas supply failing 199K BTU/h load
  • Blocked exhaust or condensate trap

How Do You Troubleshoot A. O. Smith Code 110 / 120 (Tankless) Step by Step?

Follow these 2 ordered OEM verification steps with power and gas safety checks first; escalate sealed-chamber manifold pressure measurements to a licensed gas plumber.

Sequential diagnostic steps for A. O. Smith Code 110 / 120 (Tankless)
StepDiagnostic Action
01Check gas supply pressure under full fire
02Verify condensate drain and flame rod cleanliness

What Control and Gas Pressure Thresholds Govern This Fault?

Compare measured gas manifold pressure, tankless 199,000 BTU/h startup flow, thermopile output, and T&P relief safety limits against OEM and IFGC Table 402.4 tolerances below.

Verified gas control, thermal cutoff, and OEM service baselines for A. O. Smith / Takagi Condensing Tankless
ParameterVerified ValueReference Standard
Full-Fire Condensing Input Load199,000 BTU/h / 199 CFHIFGC Table 402.4(2)
NG / LP Manifold Inlet Span3.5–10.5 in. w.c. (NG) / 8.0–13.0 in. w.c. (LP)OEM Tankless Spec
Recommended DHW Setpoint120 °FU.S. DOE / CPSC Anti-Scald
Min Flow Activation Rate0.4–0.5 GPMOEM Flow Turbine Spec
Preventive Descale Flush CycleEvery 12 months (>7.0 GPG hard water)OEM Heat Exchanger Warranty

Which Related Water Heater Blink and Error Codes Should You Compare?

Cross-check 6 other residential tank and condensing tankless fault codes if multiple indicators blink or repeat after reset.

Other residential gas and tankless diagnostic fault codes
Brand & CodeMeaningSeverity
A. O. Smith 4 Flashes (Honeywell / White-Rodgers) Thermostat / ECO over-temperature limit fault Over-Temperature Lockout
A. O. Smith 1 Flash (Every 3s) Normal operation — pilot lit and system ready Normal Status Blink
A. O. Smith 2 Flashes Thermopile voltage low (<325 mV) Pilot Signal Weak
A. O. Smith 5 Flashes Water temperature thermistor probe fault Sensor Lockout
A. O. Smith 6 Flashes Flame failure / pilot extinguished during heating Ignition Dropout
A. O. Smith 7 Flashes Flammable Vapor Sensor (FVS) / Thermal Cutout open Safety Lockout

What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What causes A. O. Smith water heater code Code 110 / 120 (Tankless)?

Ignition or flame loss fault on A. O. Smith ATI/ProLine tankless. Common root causes on A. O. Smith / Takagi Condensing Tankless include Undersized 1/2 in. gas supply failing 199K BTU/h load; Blocked exhaust or condensate trap.

How do technicians troubleshoot A. O. Smith Code 110 / 120 (Tankless)?

Verification steps: Check gas supply pressure under full fire Verify condensate drain and flame rod cleanliness Always follow 911 evacuation protocols before cycling gas or electrical controls.

Can a homeowner reset A. O. Smith Code 110 / 120 (Tankless) safely?

Scope: Licensed Gas Plumber Required. First verify gas odor absence and follow ordered visual checks before cycling power; escalate persistent lockouts to a licensed gas plumber.

What gas pressure or temperature thresholds affect A. O. Smith Code 110 / 120 (Tankless)?

Standard A. O. Smith / Takagi Condensing Tankless checks verify Full-Fire Condensing Input Load (199,000 BTU/h / 199 CFH) and NG / LP Manifold Inlet Span (3.5–10.5 in. w.c. (NG) / 8.0–13.0 in. w.c. (LP)).

Where do the engineering metrics for A. O. Smith Code 110 / 120 (Tankless) originate?

Data provenance for A. O. Smith Code 110 / 120 (Tankless) links straight to verified agency releases and OEM installation bulletins. Control family: A. O. Smith / Takagi Condensing Tankless. Severity: Ignition / Gas Lockout.

When should homeowners stop and call 911 or a pro on A. O. Smith Code 110 / 120 (Tankless)?

Online tables clarify baseline engineering limits, not site-specific hazards like live gas odors or corroded service mains. Do not open sealed gas burner compartments or bypass ECO high-limit switches without proper licensing.

Which federal regulatory baselines intersect with A. O. Smith Code 110 / 120 (Tankless)?

Check local Authority Having Jurisdiction amendments to IPC/UPC codes alongside federal EPA drinking water and 10 CFR 430 efficiency mandates.

Which incentives remain open in 2026 for plumbing equipment?

Verify active state DOE HEAR allocations (up to $1,750 for heat pump water heaters) and local utility rebates following the Dec 31, 2025 25C expiration.

Sources

  1. A. O. Smith Residential Water Heater Serial Number & Diagnostics Documentation — A. O. Smith Corporation, OEM Technical Bulletins (retrieved 2026-11-23)
  2. NFPA 54 / ANSI Z223.1 National Fuel Gas Code (Gas Pipe Sizing Ch. 6) — National Fire Protection Association, 2024 Edition (retrieved 2026-11-23)