Skip to main content
Water heater fault diagnostics

Water Heater Blink & Error Code Diagnostic Directory

Diagnostic troubleshooting index covering 61 high-frequency residential water heater blink patterns and digital error codes across Rheem, Bradford White ICON, Rinnai, Navien, and A. O. Smith. Includes gas-manifold pressure tolerances, 911 gas leak isolation rules, FHR/descaling checks, and DIY vs. pro boundaries. Every metric on this hub links directly to verified public federal agency portals, state board open-data exports, and official OEM technical specifications without paid placement.

Fault Codes Indexed
61
Gas Odor Rule
Evacuate & 911
Primary Cause
Gas / FVS / Scale
Hand turning red quarter-turn brass main water shutoff valve on three-quarter-inch copper line
Hand turning red quarter-turn brass main water shutoff valve on three-quarter-inch copper line

Which Water Heater Blink and Digital Error Codes Are Covered?

Select any verified sub-directory or technical entry below to review full specifications, official agency numbers, and applicable residential plumbing code requirements.

Rheem / Ruud — 7 Flashes

Flammable Vapor Sensor (FVS) fault or lockout

Honeywell / Resideo WV8840 Gas Valve LED

Safety Lockout (Inspect Before Reset)
Rheem / Ruud — 4 Flashes

Water temperature exceeded high-limit threshold (ECO > 190F / 88C) or thermistor fault

Honeywell WV8840 Gas Valve LED

Over-Temperature Lockout
Bradford White — 6 Flashes (+3s pause)

Thermopile voltage low (< 325 mV / pilot flame weak or dirty)

ICON System Gas Control Valve LED

Pilot / Ignition Drop-Out
Bradford White — 8 Flashes (8-2 / 8-3)

Gas valve internal relay / ECO or thermistor sensor failure

ICON System Gas Control Valve LED

Hard Lockout (Control Replacement Often Required)
Rinnai — Code 11

No ignition (burner failed to ignite within ignition trial)

Rinnai Tankless Digital Controller

Gas Supply / Ignition Lockout
Rinnai — Code LC / 00

Lime / Scale buildup detected on heat exchanger (flush reminder)

Rinnai Tankless Digital Controller

Preventive Maintenance Alert (Heat Exchanger Protection)
Navien — E003

Ignition failure (no flame sensed after 3 ignition attempts)

Navien NPE-A2 / NCB-H Front Panel

Ignition / Gas Lockout
Navien — E012

Flame loss during operation (extinguished while running)

Navien NPE-A2 / NCB-H Front Panel

Combustion / Venting Fault
A. O. Smith — 4 Flashes (Honeywell / White-Rodgers)

Thermostat / ECO over-temperature limit fault

A. O. Smith Gas Valve Status LED

Over-Temperature Lockout
Rinnai — Code 03

Power interruption during bath-fill mode

Rinnai Tankless Digital Controller

Informational / Bath Fill Reset
Rinnai — Code 10

Air supply or exhaust blockage (combustion airflow fault)

Rinnai Tankless Digital Controller

Combustion / Vent Lockout
Rinnai — Code 12

No flame / flame failure during active burner firing

Rinnai Tankless Digital Controller

Gas / Flame Loss Lockout
Rinnai — Code 14

Thermal fuse / overheat bimetal trip on heat exchanger

Rinnai Tankless Digital Controller

Safety Overheat Lockout
Rinnai — Code 16

Over-temperature warning (outgoing water exceeded safe setpoint)

Rinnai Tankless Digital Controller

High-Temp Lockout
Rinnai — Code 25

Condensate trap or float switch obstruction

Rinnai Condensing Tankless Controller

Condensate Drain Lockout
Rinnai — Code 32

Outgoing water temperature thermistor fault

Rinnai Tankless Digital Controller

Sensor Fault
Rinnai — Code 33

Heat exchanger outlet thermistor sensor fault

Rinnai Tankless Digital Controller

Sensor Fault
Rinnai — Code 52

Modulating gas valve solenoid circuit fault

Rinnai Tankless Digital Controller

Gas Control Fault
Rinnai — Code 61

Combustion fan speed / Hall-effect RPM failure

Rinnai Tankless Digital Controller

Blower Lockout
Rinnai — Code 65

Water flow control servo valve fault

Rinnai Tankless Digital Controller

Flow Control Fault
Rinnai — Code 71

Main gas solenoid valve PCB drive circuit error

Rinnai Tankless Digital Controller

Safety Control Lockout
Navien — E001

Overheating of heat exchanger (>200F high-limit)

Navien NPE-A2 / NCB-H Front Panel

High-Temp Lockout
Navien — E004

False flame detection prior to gas valve opening

Navien NPE-A2 / NCB-H Front Panel

Safety Relay Lockout
Navien — E016

Heat exchanger overheat thermal switch open

Navien NPE-A2 / NCB-H Front Panel

Overheat Safety Lockout
Navien — E030

Exhaust gas temperature over-limit (>194F PVC vent limit)

Navien NPE-A2 / NCB-H Front Panel

Exhaust Overheat Lockout
Navien — E047

Exhaust thermistor sensor error (open/short)

Navien NPE-A2 / NCB-H Front Panel

Sensor Fault
Navien — E109

Combustion fan motor RPM error

Navien NPE-A2 / NCB-H Front Panel

Blower Lockout
Navien — E110

Air Pressure Switch (APS) fault — blocked intake or exhaust

Navien NPE-A2 / NCB-H Front Panel

Airflow / Vent Lockout
Navien — E302

Inlet cold-water flow sensor / turbine error

Navien NPE-A2 / NCB-H Front Panel

Flow Sensor Fault
Navien — E407

Hot water outlet thermistor open or short circuit

Navien NPE-A2 / NCB-H Front Panel

Sensor Fault
Navien — E515

Main PCB internal microprocessor / relay failure

Navien NPE-A2 / NCB-H Front Panel

Control Board Fault
Navien — E615

Inlet water temperature sensor fault

Navien NPE-A2 / NCB-H Front Panel

Sensor Fault
Navien — E736

2-way internal/external recirculation valve fault

Navien NPE-A2 / NCB-H Front Panel

Valve Actuator Fault
Rheem / Ruud — 1 Flash (Every 3s)

Normal operation — pilot lit and thermostat satisfied

Honeywell WV8840 Gas Valve LED

Normal Status Blink
Rheem / Ruud — 2 Flashes

Thermopile voltage low (< 325 mV) — weak pilot

Honeywell WV8840 Gas Valve LED

Pilot Signal Weak
Rheem / Ruud — 5 Flashes

Temperature sensor (thermistor) fault

Honeywell WV8840 Gas Valve LED

Sensor Lockout
Rheem / Ruud — 6 Flashes

Burner failed to light or pilot flame lost

Honeywell WV8840 Gas Valve LED

Ignition Dropout
Rheem / Ruud — 8 Flashes

Gas valve internal electronics / pilot flame stuck on

Honeywell WV8840 Gas Valve LED

Hard Control Lockout
Rheem / Ruud — A004 / T004

Compressor / evaporator discharge over-temp or coil freeze

Rheem EcoNet Heat Pump Water Heater

HPWH Heat Pump Alert
Rheem / Ruud — Code 11 (Tankless)

Ignition failure on Rheem RTGH / IKONIC condensing tankless

Rheem Tankless Digital Controller

Ignition Lockout
Rheem / Ruud — Code 29 (Tankless)

Condensate drain trap full / neutralizer clogged

Rheem Tankless Digital Controller

Condensate Lockout
Bradford White — 1 Flash (Every 3s)

Normal operation — pilot lit, thermostat idle

ICON System Gas Control Valve LED

Normal Status Blink
Bradford White — 2 Flashes

Thermopile voltage weak during standby

ICON System Gas Control Valve LED

Pilot Signal Low
Bradford White — 4 Flashes

ECO high-temperature limit exceeded (>190F)

ICON System Gas Control Valve LED

Over-Temp Lockout
Bradford White — 5 Flashes

Thermistor temperature sensor fault

ICON System Gas Control Valve LED

Sensor Lockout
Bradford White — 7 Flashes

Flammable Vapor Sensor (FVS) / Thermal Reset Switch open

ICON System Gas Control Valve LED

Safety Lockout
Bradford White — 3 Flashes (Power Vent)

Pressure switch failed to close — blower/vent fault

ICON Power Vent Blower Control

Vent / Blower Lockout
A. O. Smith — 1 Flash (Every 3s)

Normal operation — pilot lit and system ready

A. O. Smith Gas Valve Status LED

Normal Status Blink
A. O. Smith — 2 Flashes

Thermopile voltage low (<325 mV)

A. O. Smith Gas Valve Status LED

Pilot Signal Weak
A. O. Smith — 5 Flashes

Water temperature thermistor probe fault

A. O. Smith Gas Valve Status LED

Sensor Lockout
A. O. Smith — 6 Flashes

Flame failure / pilot extinguished during heating

A. O. Smith Gas Valve Status LED

Ignition Dropout
A. O. Smith — 7 Flashes

Flammable Vapor Sensor (FVS) / Thermal Cutout open

A. O. Smith Gas Valve Status LED

Safety Lockout
A. O. Smith — F05 / F14 (Voltex HPWH)

Evaporator thermistor or upper/lower tank sensor fault

A. O. Smith Voltex Hybrid Control

HPWH Sensor Alert
A. O. Smith — Code 110 / 120 (Tankless)

Ignition or flame loss fault on A. O. Smith ATI/ProLine tankless

A. O. Smith / Takagi Condensing Tankless

Ignition / Gas Lockout
Noritz — Code 11

Ignition failure (no flame detected)

Noritz Remote / Digital Panel

Ignition Lockout
Noritz — Code 12

Flame loss during operation

Noritz Remote / Digital Panel

Combustion / Gas Fault
Noritz — Code 14

Overheat fuse / thermal cutoff open

Noritz Remote / Digital Panel

Overheat Safety Lockout
Noritz — Code 29

Condensate drain blockage / neutralizer full

Noritz Condensing Digital Panel

Condensate Lockout
Noritz — Code 90 / 99

Abnormal combustion / intake or exhaust airflow restriction

Noritz Remote / Digital Panel

Airflow / Vent Lockout
Takagi — Code 111 / 121

Ignition failure (111) or flame loss (121)

Takagi TM-Series Digital Controller

Gas / Ignition Lockout
Takagi — Code 611 / 711

Combustion fan speed fault (611) or gas valve PCB fault (711)

Takagi TM-Series Digital Controller

Hardware Safety Lockout

What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What data sources validate the thresholds in Water Heater Blink & Error Code Diagnostic Directory?

TapAndPipe audits Water Heater Blink & Error Code Diagnostic Directory exclusively against official .gov extracts, state contractor boards, and OEM technical documentation. Indexed across 5 primary federal, state board, or OEM manuals.

What safety boundaries apply before acting on Water Heater Blink & Error Code Diagnostic Directory?

Do not troubleshoot active gas leaks, electrical flooding, or structural sewer collapses from online guides alone—isolate hazards safely first. Follow all mandatory 911 gas leak evacuation warnings and local AHJ permit requirements.

How do 10 CFR 430, EPA PFAS, and IPC pressure rules relate to Water Heater Blink & Error Code Diagnostic Directory?

Applicable federal and model codes cover 10 CFR 430.32 fixture/heater efficiency, EPA 4.0 ppt PFAS rules, and IPC/UPC mechanical clearances.

How did Public Law 119-21 change 2026 plumbing rebates?

Federal 25C tax credits ceased for post-2025 installations under P.L. 119-21, leaving state energy office HEAR/HOMES rebates and utility bill credits.

When should a homeowner escalate Water Heater Blink & Error Code Diagnostic Directory to a state-licensed plumber?

Escalate whenever tasks involve fuel-gas piping, Category IV exhaust venting, 240V electrical circuits, main shutoff valves, or permitted sewer excavations.

Does TapAndPipe accept paid placements inside Water Heater Blink & Error Code Diagnostic Directory?

No. All specifications, state benchmarks, and contractor lists derive strictly from official public records and OEM manuals with zero paid ranking boosts.

Sources

  1. Rheem & Ruud Water Heater Status Code & Warranty Date Code Reference — Rheem Manufacturing Company, OEM Service & Diagnostic Sheets (retrieved 2026-11-23)
  2. Bradford White ICON System Diagnostic Blink Codes & Date Code Guide — Bradford White Corporation, ICON Gas Control Service Manual (retrieved 2026-11-23)
  3. Rinnai Tankless Water Heater Diagnostic Error Codes & Installation Specifications — Rinnai America Corporation, Sensei / Residential Tankless Service Manual (retrieved 2026-11-23)
  4. Navien NPE-A2 / NCB-H Condensing Tankless Error Codes & Gas Line Manual — Navien Inc., NPE-2 Series Installation & Operation Manual (retrieved 2026-11-23)
  5. A. O. Smith Residential Water Heater Serial Number & Diagnostics Documentation — A. O. Smith Corporation, OEM Technical Bulletins (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks