Skip to main content
OEM diagnostic fault code · Rinnai

Rinnai Water Heater Code 33: Meaning & Diagnostic Steps

When Rinnai Tankless Digital Controller displays Rinnai Code 33, the unit has flagged: Heat exchanger outlet thermistor sensor fault. Classified as Sensor Fault, field checks target Failed heat exchanger thermistor probe; Loose PCB harness connection. If you smell rotten-egg gas or see scorched wiring, shut off gas and power immediately and evacuate to call 911.

Fault / Blink Code
Code 33
Control Platform
Rinnai Tankless Digital Controller
Severity Class
Sensor Fault
DIY vs. Pro Scope
Pro Service Recommended
Gas & Electrical Safety Protocol If you detect a rotten-egg gas odor or observe scorched wiring, shut off the manual gas valve/breaker immediately, ventilate or evacuate, and call 911. Do not open sealed gas combustion chambers without proper licensing.
Hand turning red quarter-turn brass main water shutoff valve on three-quarter-inch copper line
Hand turning red quarter-turn brass main water shutoff valve on three-quarter-inch copper line

What Causes Rinnai Code 33?

Rinnai Code 33 triggers on Rinnai Tankless Digital Controller controls when heat exchanger outlet thermistor sensor fault. Review the primary root causes and field diagnostic checks below before ordering replacement gas or ignition parts.

  • Failed heat exchanger thermistor probe
  • Loose PCB harness connection

How Do You Troubleshoot Rinnai Code 33 Step by Step?

Follow these 2 ordered OEM verification steps with power and gas safety checks first; escalate sealed-chamber manifold pressure measurements to a licensed gas plumber.

Sequential diagnostic steps for Rinnai Code 33
StepDiagnostic Action
01Power cycle unit at breaker and inspect thermistor plug
02Replace thermistor if ohm reading deviates from OEM spec

What Control and Gas Pressure Thresholds Govern This Fault?

Compare measured gas manifold pressure, tankless 199,000 BTU/h startup flow, thermopile output, and T&P relief safety limits against OEM and IFGC Table 402.4 tolerances below.

Verified gas control, thermal cutoff, and OEM service baselines for Rinnai Tankless Digital Controller
ParameterVerified ValueReference Standard
Full-Fire Condensing Input Load199,000 BTU/h / 199 CFHIFGC Table 402.4(2)
NG / LP Manifold Inlet Span3.5–10.5 in. w.c. (NG) / 8.0–13.0 in. w.c. (LP)OEM Tankless Spec
Recommended DHW Setpoint120 °FU.S. DOE / CPSC Anti-Scald
Min Flow Activation Rate0.4–0.5 GPMOEM Flow Turbine Spec
Preventive Descale Flush CycleEvery 12 months (>7.0 GPG hard water)OEM Heat Exchanger Warranty

Which Related Water Heater Blink and Error Codes Should You Compare?

Cross-check 6 other residential tank and condensing tankless fault codes if multiple indicators blink or repeat after reset.

Other residential gas and tankless diagnostic fault codes
Brand & CodeMeaningSeverity
Rinnai Code 11 No ignition (burner failed to ignite within ignition trial) Gas Supply / Ignition Lockout
Rinnai Code LC / 00 Lime / Scale buildup detected on heat exchanger (flush reminder) Preventive Maintenance Alert (Heat Exchanger Protection)
Rinnai Code 03 Power interruption during bath-fill mode Informational / Bath Fill Reset
Rinnai Code 10 Air supply or exhaust blockage (combustion airflow fault) Combustion / Vent Lockout
Rinnai Code 12 No flame / flame failure during active burner firing Gas / Flame Loss Lockout
Rinnai Code 14 Thermal fuse / overheat bimetal trip on heat exchanger Safety Overheat Lockout

What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What causes Rinnai water heater code Code 33?

Heat exchanger outlet thermistor sensor fault. Common root causes on Rinnai Tankless Digital Controller include Failed heat exchanger thermistor probe; Loose PCB harness connection.

How do technicians troubleshoot Rinnai Code 33?

Verification steps: Power cycle unit at breaker and inspect thermistor plug Replace thermistor if ohm reading deviates from OEM spec Always follow 911 evacuation protocols before cycling gas or electrical controls.

Can a homeowner reset Rinnai Code 33 safely?

Scope: Pro Service Recommended. First verify gas odor absence and follow ordered visual checks before cycling power; escalate persistent lockouts to a licensed gas plumber.

What gas pressure or temperature thresholds affect Rinnai Code 33?

Standard Rinnai Tankless Digital Controller checks verify Full-Fire Condensing Input Load (199,000 BTU/h / 199 CFH) and NG / LP Manifold Inlet Span (3.5–10.5 in. w.c. (NG) / 8.0–13.0 in. w.c. (LP)).

Are the specifications on Rinnai Code 33 sourced from public records?

Numbers cited in Rinnai Code 33 originate from U.S. federal agencies, state licensing portals, or manufacturer specifications without invented scores. Control family: Rinnai Tankless Digital Controller. Severity: Sensor Fault.

Which conditions override general reference data for Rinnai Code 33?

Always confirm city-level code amendments and call 911 outdoors for gas odors before performing work related to Rinnai Code 33. Do not open sealed gas burner compartments or bypass ECO high-limit switches without proper licensing.

What national code ceilings govern Rinnai Code 33?

Homeowners must balance municipal IPC/UPC amendments (80 psi PRV limits, backflow testing) alongside EPA water caps and 2029 DOE heater rules.

Are DOE HEAR rebates still available after 25C expired?

Because P.L. 119-21 terminated 25C on Dec 31, 2025, 2026 incentives come through state DOE HEAR portals (<=150% AMI) and electric or water district rebates.

Sources

  1. Rinnai Tankless Water Heater Diagnostic Error Codes & Installation Specifications — Rinnai America Corporation, Sensei / Residential Tankless Service Manual (retrieved 2026-11-23)
  2. NFPA 54 / ANSI Z223.1 National Fuel Gas Code (Gas Pipe Sizing Ch. 6) — National Fire Protection Association, 2024 Edition (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks