Skip to main content
ENERGY STAR water heater model · PD 2408768

A. O. Smith GPCX-50L 1** Water Heater Specifications (0.9 UEF)

With PD 2408768 certification, A. O. Smith GPCX-50L 1** (Gas Storage, Natural Gas, Propane) achieves a certified 0.9 UEF rating across its 49-gallon nominal tank, 118 gal First Hour Rating, standing #1 of 71 across 71 peers with Pass: +0.32 / +55.2% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is American PCG62-50S65L 1** (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
118 gal
Storage Volume
49 gal
Fuel / Type
Natural Gas, Propane / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking A. O. Smith GPCX-50L 1** at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58A. O. Smith GPCX-50L 1**: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows A. O. Smith GPCX-50L 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places A. O. Smith GPCX-50L 1** at 0.9 UEF (#1 of 71; At 0.90 UEF median) in Gas Storage.

A. o. smith gpcx-50l 1** stores 49 gal nominal; 118 gal first hour rating (+23 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

In the Gas Storage tier, American PCG62-50S65L 1** (0.9 UEF, at parity) and Envirosense Enercare ENV-50N-ENER 1** (0.9 UEF, at parity) bracket A. O. Smith GPCX-50L 1**.

How Do A. O. Smith GPCX-50L 1** Specs Compare to Gas Storage Medians?

A. O. Smith GPCX-50L 1** places #1 of 71 across 71 certified Gas Storage configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408768
Model NumberGPCX-50L 1**Draw pattern: High-UsageGPCX-50L 1**
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)118 gal+23 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency92%-2.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)54.5" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2026-02-25Certified 2026-02-25Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match GPCX-50L 1** Most Closely?

These 5 competing Gas Storage units sit nearest to A. O. Smith GPCX-50L 1** by storage capacity and 0.9 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American PCG62-50S65L 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
Envirosense Enercare ENV-50N-ENER 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
Envirosense Reliance Home Comfort ENV-50N-RHC 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
Envirosense ENV-50N 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
American PCG82-50S65L 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —

Which Home Setups Are NOT a Fit for A. O. Smith GPCX-50L 1**?

Comparing A. O. Smith GPCX-50L 1** against American PCG62-50S65L 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • A. O. Smith GPCX-50L 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect A. O. Smith GPCX-50L 1**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 118 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for A. O. Smith GPCX-50L 1** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like American PCG62-50S65L 1**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

What Are the Key Questions About A. O. Smith GPCX-50L 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith GPCX-50L 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith GPCX-50L 1** logs 0.9 UEF (Pass: +0.32 / +55.2%) within the 71-unit Gas Storage group.

What physical clearance dimensions apply when installing A. O. Smith GPCX-50L 1**?

With a 54.5 in. height and 22 in. diameter, A. O. Smith GPCX-50L 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits A. O. Smith GPCX-50L 1**?

A. O. Smith GPCX-50L 1** utilizes Natural Gas, Propane combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for A. O. Smith GPCX-50L 1**?

A. O. Smith GPCX-50L 1** operates on Natural Gas, Propane (0.9 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing A. O. Smith GPCX-50L 1**?

Homes with >10.5 GPG Very Hard well water without regular 6-month sediment draining will shorten the tank life of A. O. Smith GPCX-50L 1** (Pass: +0.32 / +55.2%).

Is A. O. Smith GPCX-50L 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies A. O. Smith GPCX-50L 1** at 118 gal First Hour Rating (+23 gal vs. 95 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does A. O. Smith have active CPSC SaferProducts notices affecting GPCX-50L 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches A. O. Smith GPCX-50L 1** (0.9 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith GPCX-50L 1**. Closest peer in Gas Storage is American PCG62-50S65L 1** (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks