Certified at 3.52 UEF across its 46-gallon nominal tank, 70 gal First Hour Rating, A. O. Smith HPACO-45 1**+AXST-50STTP 1** (Hybrid/Electric Heat Pump, Electric) places #441 of 706 out of 706 ENERGY STAR models (PD 4529461). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.22 / +53.0%. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American MHPCO-45 1**+MXST-50S 1** (3.52 UEF).
- Uniform Energy Factor
- 3.52 UEF
- Cohort UEF Rank
- #441 of 706
- First Hour Rating
- 70 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.22 / +53.0%

Tested at 3.52 UEF, A. O. Smith HPACO-45 1**+AXST-50STTP 1** places #441 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.18 UEF vs. 3.70 UEF median).
A. O. Smith HPACO-45 1**+AXST-50STTP 1** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.22 UEF (+53.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for A. O. Smith HPACO-45 1**+AXST-50STTP 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPACO-45 1**+AXST-50STTP 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to A. O. Smith HPACO-45 1**+AXST-50STTP 1** include American MHPCO-45 1**+MXST-50S 1** (3.52 UEF, at parity) alongside Giant GTHPCO-45 1**+GTXST-50S 1** (3.52 UEF, at parity).
How Do A. O. Smith HPACO-45 1**+AXST-50STTP 1** Specs Compare to Hybrid/Electric Heat Pump Medians?
A. O. Smith HPACO-45 1**+AXST-50STTP 1** places #441 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 4529461 |
| Model Number | HPACO-45 1**+AXST-50STTP 1** | Draw pattern: Medium-Usage | HPACO-45 1**+AXST-50STTP 1** |
| Uniform Energy Factor (UEF) | 3.52 | -0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 70 gal | -2 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 923 kWh/yr | -149 kWh/yr vs. 1,072 kWh/yr median | Est. $168/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 429% | At 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.6" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
What Does HPACO-45 1**+AXST-50STTP 1** Cost to Operate Across State Electricity Rates?
At 923 kWh/yr, A. O. Smith HPACO-45 1**+AXST-50STTP 1** runs roughly $168/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $168/yr | $1,676 | $4,736 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $435/yr | $4,355 | $12,305 |
| California | 29.75 ¢/kWh ($0.2975) | $275/yr | $2,746 | $7,759 |
| Texas | 15.91 ¢/kWh ($0.1591) | $147/yr | $1,468 | $4,149 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $135/yr | $1,350 | $3,816 |
Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match HPACO-45 1**+AXST-50STTP 1** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith HPACO-45 1**+AXST-50STTP 1** by storage capacity and 3.52 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American MHPCO-45 1**+MXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| Giant GTHPCO-45 1**+GTXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| John Wood JWHPCO-45 1**+JWXST-50S 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
| American MHPCO-45 1**+MXST-50STTP 1** | Hybrid/Electric Heat Pump | 46 gal | 70 gal | 3.52 (at parity) | 923 |
What Are the Limitations of A. O. Smith HPACO-45 1**+AXST-50STTP 1** and Who Should Not Install It?
Before ordering A. O. Smith HPACO-45 1**+AXST-50STTP 1** (Hybrid/Electric Heat Pump, 3.52 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- A. O. Smith HPACO-45 1**+AXST-50STTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPACO-45 1**+AXST-50STTP 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About A. O. Smith HPACO-45 1**+AXST-50STTP 1**?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does A. O. Smith HPACO-45 1**+AXST-50STTP 1** pass the May 6, 2029 federal DOE efficiency rule?
A. O. Smith HPACO-45 1**+AXST-50STTP 1** carries a verified 3.52 UEF rating (Pass: +1.22 / +53.0%), ranking #441 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does A. O. Smith HPACO-45 1**+AXST-50STTP 1** need?
A. O. Smith HPACO-45 1**+AXST-50STTP 1** stands 46.6 in. high with a 18 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does A. O. Smith HPACO-45 1**+AXST-50STTP 1** require?
A. O. Smith HPACO-45 1**+AXST-50STTP 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does A. O. Smith HPACO-45 1**+AXST-50STTP 1** cost per year to run?
Rated at 923 kWh/yr, A. O. Smith HPACO-45 1**+AXST-50STTP 1** costs about $168/yr ($1,680 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).
Who should NOT install A. O. Smith HPACO-45 1**+AXST-50STTP 1**, and what are its limits?
A. O. Smith HPACO-45 1**+AXST-50STTP 1** (3.52 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can A. O. Smith HPACO-45 1**+AXST-50STTP 1** serve at peak demand?
A. O. Smith HPACO-45 1**+AXST-50STTP 1** achieves a 70 gal First Hour Rating (-2 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for A. O. Smith HPACO-45 1**+AXST-50STTP 1**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to A. O. Smith HPACO-45 1**+AXST-50STTP 1**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American MHPCO-45 1**+MXST-50S 1** (3.52 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)