Skip to main content
ENERGY STAR water heater model · PD 4529478

Giant GTHPCO-45 1**+GTXST-50S 1** Water Heater Specifications (3.52 UEF)

With PD 4529478 certification, Giant GTHPCO-45 1**+GTXST-50S 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.52 UEF rating across its 46-gallon nominal tank, 70 gal First Hour Rating, standing #441 of 706 across 706 peers with Pass: +1.22 / +53.0% for May 6, 2029. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
70 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Giant GTHPCO-45 1**+GTXST-50S 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Giant GTHPCO-45 1**+GTXST-50S 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Giant GTHPCO-45 1**+GTXST-50S 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Giant GTHPCO-45 1**+GTXST-50S 1** at 3.52 UEF (#441 of 706; -0.18 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Giant GTHPCO-45 1**+GTXST-50S 1** stands +1.22 UEF (+53.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for Giant GTHPCO-45 1**+GTXST-50S 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Giant GTHPCO-45 1**+GTXST-50S 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50S 1** (3.52 UEF, at parity) bracket Giant GTHPCO-45 1**+GTXST-50S 1**.

How Complete Are the Certified Metrics for Giant GTHPCO-45 1**+GTXST-50S 1**?

Standing at #441 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Giant GTHPCO-45 1**+GTXST-50S 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGiant12 certified listingsENERGY STAR PD 4529478
Model NumberGTHPCO-45 1**+GTXST-50S 1**Draw pattern: Medium-UsageGTHPCO-45 1**+GTXST-50S 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)70 gal-2 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency429%At 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.6" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-19Certified 2026-03-19Markets: United States, Canada

What Is the Projected Utility Bill for GTHPCO-45 1**+GTXST-50S 1** by State?

At 923 kWh/yr, Giant GTHPCO-45 1**+GTXST-50S 1** averages about $168/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Giant Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Giant in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to GTHPCO-45 1**+GTXST-50S 1**?

Ordered by minimal capacity and UEF spread relative to Giant GTHPCO-45 1**+GTXST-50S 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
American MHPCO-45 1**+MXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
GSW WATER HEATERS GHPCO-45 1**+GXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
John Wood JWHPCO-45 1**+JWXST-50S 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50STTP 1** Hybrid/Electric Heat Pump 46 gal 70 gal 3.52 (at parity) 923

What Are the Limitations of Giant GTHPCO-45 1**+GTXST-50S 1** and Who Should Not Install It?

Before ordering Giant GTHPCO-45 1**+GTXST-50S 1** (Hybrid/Electric Heat Pump, 3.52 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Giant GTHPCO-45 1**+GTXST-50S 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Giant GTHPCO-45 1**+GTXST-50S 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Giant GTHPCO-45 1**+GTXST-50S 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50S 1** footprint.

Practical Specs & Code Questions for Giant GTHPCO-45 1**+GTXST-50S 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Giant GTHPCO-45 1**+GTXST-50S 1** pass the May 6, 2029 federal DOE efficiency rule?

Giant GTHPCO-45 1**+GTXST-50S 1** carries a verified 3.52 UEF rating (Pass: +1.22 / +53.0%), ranking #441 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does Giant GTHPCO-45 1**+GTXST-50S 1** need?

Giant GTHPCO-45 1**+GTXST-50S 1** stands 46.6 in. high with a 18 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Giant GTHPCO-45 1**+GTXST-50S 1** require?

Giant GTHPCO-45 1**+GTXST-50S 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does Giant GTHPCO-45 1**+GTXST-50S 1** cost per year to run?

Rated at 923 kWh/yr, Giant GTHPCO-45 1**+GTXST-50S 1** costs about $168/yr ($1,680 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).

Who should NOT install Giant GTHPCO-45 1**+GTXST-50S 1**, and what are its limits?

Giant GTHPCO-45 1**+GTXST-50S 1** (3.52 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can Giant GTHPCO-45 1**+GTXST-50S 1** serve at peak demand?

Giant GTHPCO-45 1**+GTXST-50S 1** achieves a 70 gal First Hour Rating (-2 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Giant GTHPCO-45 1**+GTXST-50S 1**?

No active CPSC recalls matched Giant as of 2026-11-23. Always decode the serial tag on Giant GTHPCO-45 1**+GTXST-50S 1** because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Giant GTHPCO-45 1**+GTXST-50S 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50S 1** (3.52 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks