Skip to main content
ENERGY STAR water heater model · PD 3626855

ACIQ ACIQ-80G-HP-WH Water Heater Specifications (4 UEF)

The ACIQ ACIQ-80G-HP-WH (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating, ranking #106 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3626855). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.50 / +60.0%. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
74 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking ACIQ ACIQ-80G-HP-WH at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50ACIQ ACIQ-80G-HP-WH: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows ACIQ ACIQ-80G-HP-WH relative to the cohort median.
Efficiency comparison & rule summary

ACIQ ACIQ-80G-HP-WH (4.0 UEF) ranks #106 of 706 Hybrid/Electric Heat Pump models — 35-way tie; top 19.8%, more efficient than 80.2% of Hybrid/Electric Heat Pump models, +0.30 UEF above the 3.70 UEF median.

Federal 2029 margin for ACIQ ACIQ-80G-HP-WH: +1.50 UEF (+60.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for ACIQ ACIQ-80G-HP-WH runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for ACIQ ACIQ-80G-HP-WH: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: ACIQ ACIQ-80G-HP-WH (4.0 UEF) compares closely with 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and Bosch TR7000T - 80CA (4.0 UEF, at parity).

Which Specs Set ACIQ ACIQ-80G-HP-WH Apart From Cohort Averages?

Ranked #106 of 706 (top 19.8%) inside the 706-model Hybrid/Electric Heat Pump cohort, ACIQ ACIQ-80G-HP-WH is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandACIQ2 certified listingsENERGY STAR PD 3626855
Model NumberACIQ-80G-HP-WHDraw pattern: High-UsageACIQ-80G-HP-WH
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-11Certified 2024-11-11Markets: United States, Canada

How Do Regional kWh Prices Impact ACIQ-80G-HP-WH Over 10 Years?

Using EIA Table 5.6.A benchmarks, ACIQ ACIQ-80G-HP-WH's 1,240 kWh/yr draw translates to roughly $225/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,538
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $19,584
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $12,349
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,604
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $6,073
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should ACIQ Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for ACIQ; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80CA Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Custom Comfort CCOHPWH80A Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
DIYCOOL ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80US Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240

What Installation Caveats Apply Before Buying ACIQ ACIQ-80G-HP-WH?

Even high-UEF units like ACIQ ACIQ-80G-HP-WH (4.0 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • ACIQ ACIQ-80G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting ACIQ ACIQ-80G-HP-WH directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing ACIQ ACIQ-80G-HP-WH Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

Frequently Asked Technical Questions: ACIQ ACIQ-80G-HP-WH

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is ACIQ ACIQ-80G-HP-WH eligible for continued manufacture past May 6, 2029?

At 4.0 UEF, ACIQ ACIQ-80G-HP-WH achieves Pass: +1.50 / +60.0% for the 2029 DOE standard and stands #106 of 706 (top 19.8%) against 1HVAC ACIQ-80G-HP-WH and Bosch TR7000T - 80CA.

How tall and wide is ACIQ ACIQ-80G-HP-WH, and what service clearance is needed?

Physical dimensions for ACIQ ACIQ-80G-HP-WH are 41.7 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

Will ACIQ ACIQ-80G-HP-WH require upgrading household electrical panels or gas piping?

ACIQ ACIQ-80G-HP-WH draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is ACIQ ACIQ-80G-HP-WH economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $225/yr ($2,250 over 10 years) to power ACIQ ACIQ-80G-HP-WH at 1,240 kWh/yr under the 18.16 cents/kWh US average (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

Which installation bottlenecks limit ACIQ ACIQ-80G-HP-WH?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, ACIQ ACIQ-80G-HP-WH drops into resistance mode more often.

How does ACIQ ACIQ-80G-HP-WH handle simultaneous showers and laundry?

Delivering 91 gal in the first hour (+19 gal vs. 72 gal median), ACIQ ACIQ-80G-HP-WH combines 74 gal tank storage with rapid burner/element recovery.

How long is the warranty on ACIQ ACIQ-80G-HP-WH and how do you decode its serial?

CPSC records show 0 active plumbing recalls for ACIQ as of 2026-11-23. Confirm install proof and serial manufacture year on ACIQ ACIQ-80G-HP-WH before calling service.

How do 2026 post-OBBBA rebates affect buying ACIQ ACIQ-80G-HP-WH?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks