Skip to main content
ENERGY STAR water heater model · PD 3626847

DIYCOOL ACIQ-80G-HP-WH Water Heater Specifications (4 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, DIYCOOL ACIQ-80G-HP-WH achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating and ranks #106 of 706 in its 706-model cohort (PD 3626847), recording Pass: +1.50 / +60.0% under 2029 DOE rules. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
74 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking DIYCOOL ACIQ-80G-HP-WH at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50DIYCOOL ACIQ-80G-HP-WH: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows DIYCOOL ACIQ-80G-HP-WH relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, DIYCOOL ACIQ-80G-HP-WH logs 4.0 UEF and ranks #106 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), DIYCOOL ACIQ-80G-HP-WH holds a +1.50 UEF (+60.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for DIYCOOL ACIQ-80G-HP-WH runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for DIYCOOL ACIQ-80G-HP-WH: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping DIYCOOL ACIQ-80G-HP-WH (4.0 UEF)? Check 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity).

How Complete Are the Certified Metrics for DIYCOOL ACIQ-80G-HP-WH?

Standing at #106 of 706 (top 19.8%) among 706 certified Hybrid/Electric Heat Pump heaters, DIYCOOL ACIQ-80G-HP-WH brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandDIYCOOL2 certified listingsENERGY STAR PD 3626847
Model NumberACIQ-80G-HP-WHDraw pattern: High-UsageACIQ-80G-HP-WH
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-11Certified 2024-11-11Markets: United States, Canada

What Is the Projected Utility Bill for ACIQ-80G-HP-WH by State?

At 1,240 kWh/yr, DIYCOOL ACIQ-80G-HP-WH averages about $225/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,538
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $19,584
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $12,349
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,604
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $6,073
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are DIYCOOL Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched DIYCOOL in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to ACIQ-80G-HP-WH?

Ordered by minimal capacity and UEF spread relative to DIYCOOL ACIQ-80G-HP-WH, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
ACIQ ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80CA Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Custom Comfort CCOHPWH80A Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80US Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240

Who Is DIYCOOL ACIQ-80G-HP-WH Best For — and When Should You Pick 1HVAC ACIQ-80G-HP-WH?

Evaluate whether DIYCOOL ACIQ-80G-HP-WH's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • DIYCOOL ACIQ-80G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting DIYCOOL ACIQ-80G-HP-WH directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing DIYCOOL ACIQ-80G-HP-WH Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

Practical Specs & Code Questions for DIYCOOL ACIQ-80G-HP-WH

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does DIYCOOL ACIQ-80G-HP-WH (4.0 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, DIYCOOL ACIQ-80G-HP-WH records 4.0 UEF (Pass: +1.50 / +60.0%), placing #106 of 706 (top 19.8%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does DIYCOOL ACIQ-80G-HP-WH fit inside a tight hallway closet or low-headroom utility room?

DIYCOOL ACIQ-80G-HP-WH requires room for its 41.7 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern DIYCOOL ACIQ-80G-HP-WH?

For DIYCOOL ACIQ-80G-HP-WH, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for DIYCOOL ACIQ-80G-HP-WH?

Using 1,240 kWh/yr, DIYCOOL ACIQ-80G-HP-WH generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of DIYCOOL ACIQ-80G-HP-WH (4.0 UEF)?

DIYCOOL ACIQ-80G-HP-WH requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or 1HVAC ACIQ-80G-HP-WH.

What hot-water delivery rating governs DIYCOOL ACIQ-80G-HP-WH?

Rated for 91 gal FHR (+19 gal vs. 72 gal median), DIYCOOL ACIQ-80G-HP-WH prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen DIYCOOL ACIQ-80G-HP-WH for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for DIYCOOL; use our browser-only serial decoder to inspect DIYCOOL ACIQ-80G-HP-WH's age and warranty window.

What alternative models sit closest to DIYCOOL ACIQ-80G-HP-WH in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks