Engineered as a Electric Hybrid/Electric Heat Pump unit, DIYCOOL ACIQ-80G-HP-WH achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating and ranks #106 of 706 in its 706-model cohort (PD 3626847), recording Pass: +1.50 / +60.0% under 2029 DOE rules. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).
- Uniform Energy Factor
- 4.0 UEF
- Cohort UEF Rank
- #106 of 706 (top 19.8%)
- First Hour Rating
- 91 gal
- Storage Volume
- 74 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.50 / +60.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, DIYCOOL ACIQ-80G-HP-WH logs 4.0 UEF and ranks #106 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), DIYCOOL ACIQ-80G-HP-WH holds a +1.50 UEF (+60.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for DIYCOOL ACIQ-80G-HP-WH runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for DIYCOOL ACIQ-80G-HP-WH: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping DIYCOOL ACIQ-80G-HP-WH (4.0 UEF)? Check 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity).
How Complete Are the Certified Metrics for DIYCOOL ACIQ-80G-HP-WH?
Standing at #106 of 706 (top 19.8%) among 706 certified Hybrid/Electric Heat Pump heaters, DIYCOOL ACIQ-80G-HP-WH brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | DIYCOOL | 2 certified listings | ENERGY STAR PD 3626847 |
| Model Number | ACIQ-80G-HP-WH | Draw pattern: High-Usage | ACIQ-80G-HP-WH |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,240 kWh/yr | +168 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 41.7" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-11 | Certified 2024-11-11 | Markets: United States, Canada |
What Is the Projected Utility Bill for ACIQ-80G-HP-WH by State?
At 1,240 kWh/yr, DIYCOOL ACIQ-80G-HP-WH averages about $225/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,252 | $7,538 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $585/yr | $5,850 | $19,584 |
| California | 29.75 ¢/kWh ($0.2975) | $369/yr | $3,689 | $12,349 |
| Texas | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,973 | $6,604 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,814 | $6,073 |
Are DIYCOOL Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched DIYCOOL in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to ACIQ-80G-HP-WH?
Ordered by minimal capacity and UEF spread relative to DIYCOOL ACIQ-80G-HP-WH, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| 1HVAC ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| ACIQ ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Bosch TR7000T - 80CA | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Custom Comfort CCOHPWH80A | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| Bosch TR7000T - 80US | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
Who Is DIYCOOL ACIQ-80G-HP-WH Best For — and When Should You Pick 1HVAC ACIQ-80G-HP-WH?
Evaluate whether DIYCOOL ACIQ-80G-HP-WH's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- DIYCOOL ACIQ-80G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting DIYCOOL ACIQ-80G-HP-WH directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for DIYCOOL ACIQ-80G-HP-WH
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does DIYCOOL ACIQ-80G-HP-WH (4.0 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, DIYCOOL ACIQ-80G-HP-WH records 4.0 UEF (Pass: +1.50 / +60.0%), placing #106 of 706 (top 19.8%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does DIYCOOL ACIQ-80G-HP-WH fit inside a tight hallway closet or low-headroom utility room?
DIYCOOL ACIQ-80G-HP-WH requires room for its 41.7 in. vertical shell and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern DIYCOOL ACIQ-80G-HP-WH?
For DIYCOOL ACIQ-80G-HP-WH, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for DIYCOOL ACIQ-80G-HP-WH?
Using 1,240 kWh/yr, DIYCOOL ACIQ-80G-HP-WH generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of DIYCOOL ACIQ-80G-HP-WH (4.0 UEF)?
DIYCOOL ACIQ-80G-HP-WH requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or 1HVAC ACIQ-80G-HP-WH.
What hot-water delivery rating governs DIYCOOL ACIQ-80G-HP-WH?
Rated for 91 gal FHR (+19 gal vs. 72 gal median), DIYCOOL ACIQ-80G-HP-WH prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen DIYCOOL ACIQ-80G-HP-WH for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for DIYCOOL; use our browser-only serial decoder to inspect DIYCOOL ACIQ-80G-HP-WH's age and warranty window.
What alternative models sit closest to DIYCOOL ACIQ-80G-HP-WH in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)