Skip to main content
ENERGY STAR water heater model · PD 2683732

AMERICAN STANDARD WATER HEATERS ASHPWH-65***** Water Heater Specifications (3.85 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** achieves a certified 3.85 UEF rating across its 62-gallon nominal tank, 78 gal First Hour Rating and ranks #217 of 706 in its 706-model cohort (PD 2683732), recording Pass: +1.35 / +54.0% under 2029 DOE rules. Rated annual electricity draw of 1,289 kWh/yr equates to roughly $234/yr ($2,341 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-65 (3.85 UEF).

Uniform Energy Factor
3.85 UEF
Cohort UEF Rank
#217 of 706 (top 31.2%)
First Hour Rating
78 gal
Storage Volume
62 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.35 / +54.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking AMERICAN STANDARD WATER HEATERS ASHPWH-65***** at 3.85 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50AMERICAN STANDARD WATER HEATERS ASHPWH-65*****: 3.85
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows AMERICAN STANDARD WATER HEATERS ASHPWH-65***** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** logs 3.85 UEF and ranks #217 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), AMERICAN STANDARD WATER HEATERS ASHPWH-65***** holds a +1.35 UEF (+54.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,289 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-65***** runs ~$234/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-65*****: 10-year operating spend spans $1,886 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,082 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-65***** (3.85 UEF)? Check Ariston ARIHPWH-65 (3.85 UEF, at parity) and Midea CAN3-RSJ-15/250RDVN3-L4 (4.0 UEF, delta +0.15).

What Physical and Thermal Ratings Define AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?

Positioning at #217 of 706 (top 31.2%) out of 706 Hybrid/Electric Heat Pump peers, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAMERICAN STANDARD WATER HEATERS4 certified listingsENERGY STAR PD 2683732
Model NumberASHPWH-65*****Draw pattern: High-UsageASHPWH-65*****
Uniform Energy Factor (UEF)3.85+0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)78 gal+6 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,289 kWh/yr+217 kWh/yr vs. 1,072 kWh/yr medianEst. $234/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)50" H x 20.2" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-02-04Certified 2026-02-04Markets: United States, Canada

Why Do State Utility Rates Shift ASHPWH-65***** Running Costs?

Consuming 1,289 kWh annually puts AMERICAN STANDARD WATER HEATERS ASHPWH-65***** near $234/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,289 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$234.00/yrHawaii$608.00/yrCalifornia$383.00/yrTexas$205.00/yrWashington$189.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $234/yr $2,341 $7,455
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $608/yr $6,082 $19,367
California 29.75 ¢/kWh ($0.2975) $383/yr $3,835 $12,212
Texas 15.91 ¢/kWh ($0.1591) $205/yr $2,051 $6,531
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $189/yr $1,886 $6,006
Estimated electricity spend (1,289 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any AMERICAN STANDARD WATER HEATERS Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under AMERICAN STANDARD WATER HEATERS; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?

Homeowners cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-65***** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Ariston ARIHPWH-65 Hybrid/Electric Heat Pump 62 gal 78 gal 3.85 (at parity) 1,289
Midea CAN3-RSJ-15/250RDVN3-L4 Hybrid/Electric Heat Pump 61 gal 80 gal 4.0 (+0.15) 1,234
Rinnai REHP65CW* Hybrid/Electric Heat Pump 61 gal 80 gal 4.0 (+0.15) 1,234
Navien NWP500S065AUMB Hybrid/Electric Heat Pump 61 gal 80 gal 4.03 (+0.18) 1,245
Midea MAHW-65VN3B Hybrid/Electric Heat Pump 61 gal 80 gal 4.0 (+0.15) 1,234

What Installation Caveats Apply Before Buying AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?

Even high-UEF units like AMERICAN STANDARD WATER HEATERS ASHPWH-65***** (3.85 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • AMERICAN STANDARD WATER HEATERS ASHPWH-65***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-65***** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing AMERICAN STANDARD WATER HEATERS ASHPWH-65***** Strong Fit — 3.85 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Ariston ARIHPWH-65 footprint.

Sizing, Efficiency & Recall Answers for AMERICAN STANDARD WATER HEATERS ASHPWH-65*****

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is AMERICAN STANDARD WATER HEATERS ASHPWH-65***** eligible for continued manufacture past May 6, 2029?

At 3.85 UEF, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** achieves Pass: +1.35 / +54.0% for the 2029 DOE standard and stands #217 of 706 (top 31.2%) against Ariston ARIHPWH-65 and Midea CAN3-RSJ-15/250RDVN3-L4.

How tall and wide is AMERICAN STANDARD WATER HEATERS ASHPWH-65*****, and what service clearance is needed?

Physical dimensions for AMERICAN STANDARD WATER HEATERS ASHPWH-65***** are 50 in. height and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)); verify stair turns and drain pan width before delivery.

Will AMERICAN STANDARD WATER HEATERS ASHPWH-65***** require upgrading household electrical panels or gas piping?

AMERICAN STANDARD WATER HEATERS ASHPWH-65***** draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is AMERICAN STANDARD WATER HEATERS ASHPWH-65***** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $234/yr ($2,340 over 10 years) to power AMERICAN STANDARD WATER HEATERS ASHPWH-65***** at 1,289 kWh/yr under the 18.16 cents/kWh US average (ranging from $189/yr in Washington hydro tiers up to $608/yr in Hawaii).

Which installation bottlenecks limit AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** drops into resistance mode more often.

How does AMERICAN STANDARD WATER HEATERS ASHPWH-65***** handle simultaneous showers and laundry?

Delivering 78 gal in the first hour (+6 gal vs. 72 gal median), AMERICAN STANDARD WATER HEATERS ASHPWH-65***** combines 62 gal tank storage with rapid burner/element recovery.

How long is the warranty on AMERICAN STANDARD WATER HEATERS ASHPWH-65***** and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-65 (3.85 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks