AMERICAN STANDARD WATER HEATERS ASHPWH-65***** Water Heater Specifications (3.85 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** achieves a certified 3.85 UEF rating across its 62-gallon nominal tank, 78 gal First Hour Rating and ranks #217 of 706 in its 706-model cohort (PD 2683732), recording Pass: +1.35 / +54.0% under 2029 DOE rules. Rated annual electricity draw of 1,289 kWh/yr equates to roughly $234/yr ($2,341 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-65 (3.85 UEF).
- Uniform Energy Factor
- 3.85 UEF
- Cohort UEF Rank
- #217 of 706 (top 31.2%)
- First Hour Rating
- 78 gal
- Storage Volume
- 62 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.35 / +54.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** logs 3.85 UEF and ranks #217 of 706.
Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), AMERICAN STANDARD WATER HEATERS ASHPWH-65***** holds a +1.35 UEF (+54.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,289 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-65***** runs ~$234/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-65*****: 10-year operating spend spans $1,886 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,082 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-65***** (3.85 UEF)? Check Ariston ARIHPWH-65 (3.85 UEF, at parity) and Midea CAN3-RSJ-15/250RDVN3-L4 (4.0 UEF, delta +0.15).
What Physical and Thermal Ratings Define AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?
Positioning at #217 of 706 (top 31.2%) out of 706 Hybrid/Electric Heat Pump peers, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | AMERICAN STANDARD WATER HEATERS | 4 certified listings | ENERGY STAR PD 2683732 |
| Model Number | ASHPWH-65***** | Draw pattern: High-Usage | ASHPWH-65***** |
| Uniform Energy Factor (UEF) | 3.85 | +0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 78 gal | +6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,289 kWh/yr | +217 kWh/yr vs. 1,072 kWh/yr median | Est. $234/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 50" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-04 | Certified 2026-02-04 | Markets: United States, Canada |
Why Do State Utility Rates Shift ASHPWH-65***** Running Costs?
Consuming 1,289 kWh annually puts AMERICAN STANDARD WATER HEATERS ASHPWH-65***** near $234/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $234/yr | $2,341 | $7,455 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $608/yr | $6,082 | $19,367 |
| California | 29.75 ¢/kWh ($0.2975) | $383/yr | $3,835 | $12,212 |
| Texas | 15.91 ¢/kWh ($0.1591) | $205/yr | $2,051 | $6,531 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $189/yr | $1,886 | $6,006 |
Have Any AMERICAN STANDARD WATER HEATERS Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 2 brand notices under AMERICAN STANDARD WATER HEATERS; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?
Homeowners cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-65***** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Ariston ARIHPWH-65 | Hybrid/Electric Heat Pump | 62 gal | 78 gal | 3.85 (at parity) | 1,289 |
| Midea CAN3-RSJ-15/250RDVN3-L4 | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (+0.15) | 1,234 |
| Rinnai REHP65CW* | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (+0.15) | 1,234 |
| Navien NWP500S065AUMB | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.03 (+0.18) | 1,245 |
| Midea MAHW-65VN3B | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (+0.15) | 1,234 |
What Installation Caveats Apply Before Buying AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?
Even high-UEF units like AMERICAN STANDARD WATER HEATERS ASHPWH-65***** (3.85 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- AMERICAN STANDARD WATER HEATERS ASHPWH-65***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-65***** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for AMERICAN STANDARD WATER HEATERS ASHPWH-65*****
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is AMERICAN STANDARD WATER HEATERS ASHPWH-65***** eligible for continued manufacture past May 6, 2029?
At 3.85 UEF, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** achieves Pass: +1.35 / +54.0% for the 2029 DOE standard and stands #217 of 706 (top 31.2%) against Ariston ARIHPWH-65 and Midea CAN3-RSJ-15/250RDVN3-L4.
How tall and wide is AMERICAN STANDARD WATER HEATERS ASHPWH-65*****, and what service clearance is needed?
Physical dimensions for AMERICAN STANDARD WATER HEATERS ASHPWH-65***** are 50 in. height and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)); verify stair turns and drain pan width before delivery.
Will AMERICAN STANDARD WATER HEATERS ASHPWH-65***** require upgrading household electrical panels or gas piping?
AMERICAN STANDARD WATER HEATERS ASHPWH-65***** draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is AMERICAN STANDARD WATER HEATERS ASHPWH-65***** economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $234/yr ($2,340 over 10 years) to power AMERICAN STANDARD WATER HEATERS ASHPWH-65***** at 1,289 kWh/yr under the 18.16 cents/kWh US average (ranging from $189/yr in Washington hydro tiers up to $608/yr in Hawaii).
Which installation bottlenecks limit AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, AMERICAN STANDARD WATER HEATERS ASHPWH-65***** drops into resistance mode more often.
How does AMERICAN STANDARD WATER HEATERS ASHPWH-65***** handle simultaneous showers and laundry?
Delivering 78 gal in the first hour (+6 gal vs. 72 gal median), AMERICAN STANDARD WATER HEATERS ASHPWH-65***** combines 62 gal tank storage with rapid burner/element recovery.
How long is the warranty on AMERICAN STANDARD WATER HEATERS ASHPWH-65***** and how do you decode its serial?
CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-65 (3.85 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)