Ariston ARIHPWH-65 Water Heater Specifications (3.85 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Ariston ARIHPWH-65 (Electric) achieves a certified 3.85 UEF rating across its 62-gallon nominal tank, 78 gal First Hour Rating (rank #217 of 706, PD 3942614) and verifies as Pass: +1.35 / +54.0% for 2029 DOE floors. Rated annual electricity draw of 1,289 kWh/yr equates to roughly $234/yr ($2,341 over 10 years) at 18.16 cents/kWh. Closest certified alternative is AMERICAN STANDARD WATER HEATERS ASHPWH-65***** (3.85 UEF).
- Uniform Energy Factor
- 3.85 UEF
- Cohort UEF Rank
- #217 of 706 (top 31.2%)
- First Hour Rating
- 78 gal
- Storage Volume
- 62 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.35 / +54.0%

Ariston ARIHPWH-65 records 3.85 UEF efficiency, putting it #217 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Ariston ARIHPWH-65 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.35 UEF (+54.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,289 kWh/yr for Ariston ARIHPWH-65 runs ~$234/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ariston ARIHPWH-65: 10-year operating spend spans $1,886 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,082 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Ariston ARIHPWH-65 (3.85 UEF) are AMERICAN STANDARD WATER HEATERS ASHPWH-65***** (3.85 UEF, at parity) and Midea CAN3-RSJ-15/250RDVN3-L4 (4.0 UEF, delta +0.15).
How Do Ariston ARIHPWH-65 Specs Compare to Hybrid/Electric Heat Pump Medians?
Ariston ARIHPWH-65 places #217 of 706 (top 31.2%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ariston | 8 certified listings | ENERGY STAR PD 3942614 |
| Model Number | ARIHPWH-65 | Draw pattern: High-Usage | ARIHPWH-65 |
| Uniform Energy Factor (UEF) | 3.85 | +0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 78 gal | +6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,289 kWh/yr | +217 kWh/yr vs. 1,072 kWh/yr median | Est. $234/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 50" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-04 | Certified 2026-02-04 | Markets: United States, Canada |
What Does ARIHPWH-65 Cost to Operate Across State Electricity Rates?
At 1,289 kWh/yr, Ariston ARIHPWH-65 runs roughly $234/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $234/yr | $2,341 | $7,455 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $608/yr | $6,082 | $19,367 |
| California | 29.75 ¢/kWh ($0.2975) | $383/yr | $3,835 | $12,212 |
| Texas | 15.91 ¢/kWh ($0.1591) | $205/yr | $2,051 | $6,531 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $189/yr | $1,886 | $6,006 |
Are There Active CPSC Safety Recalls for Ariston Water Heaters?
Zero active CPSC recalls matched Ariston in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.
Which Certified Water Heaters Match ARIHPWH-65 Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Ariston ARIHPWH-65 by storage capacity and 3.85 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| AMERICAN STANDARD WATER HEATERS ASHPWH-65***** | Hybrid/Electric Heat Pump | 62 gal | 78 gal | 3.85 (at parity) | 1,289 |
| Midea CAN3-RSJ-15/250RDVN3-L4 | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (+0.15) | 1,234 |
| Rinnai REHP65CW* | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (+0.15) | 1,234 |
| Navien NWP500S065AUMB | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.03 (+0.18) | 1,245 |
| Midea MAHW-65VN3B | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (+0.15) | 1,234 |
Who Is Ariston ARIHPWH-65 Best For — and When Should You Pick AMERICAN STANDARD WATER HEATERS ASHPWH-65*****?
Evaluate whether Ariston ARIHPWH-65's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Ariston ARIHPWH-65 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ariston ARIHPWH-65 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Ariston ARIHPWH-65?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Ariston ARIHPWH-65 (3.85 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Ariston ARIHPWH-65 records 3.85 UEF (Pass: +1.35 / +54.0%), placing #217 of 706 (top 31.2%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Ariston ARIHPWH-65 fit inside a tight hallway closet or low-headroom utility room?
Ariston ARIHPWH-65 requires room for its 50 in. vertical shell and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Ariston ARIHPWH-65?
For Ariston ARIHPWH-65, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Ariston ARIHPWH-65?
Using 1,289 kWh/yr, Ariston ARIHPWH-65 generates an estimated $234/yr electric bill at 18.16 cents/kWh (ranging from $189/yr in Washington hydro tiers up to $608/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Ariston ARIHPWH-65 (3.85 UEF)?
Ariston ARIHPWH-65 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or AMERICAN STANDARD WATER HEATERS ASHPWH-65*****.
What hot-water delivery rating governs Ariston ARIHPWH-65?
Rated for 78 gal FHR (+6 gal vs. 72 gal median), Ariston ARIHPWH-65 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Ariston ARIHPWH-65 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Ariston; use our browser-only serial decoder to inspect Ariston ARIHPWH-65's age and warranty window.
What alternative models sit closest to Ariston ARIHPWH-65 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is AMERICAN STANDARD WATER HEATERS ASHPWH-65***** (3.85 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)