American HPHE10280H045DVCTA-1** Water Heater Specifications (3.45 UEF)
With PD 2408858 certification, American HPHE10280H045DVCTA-1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 86 gal First Hour Rating, standing #563 of 706 across 706 peers with Pass: +0.95 / +38.0% for May 6, 2029. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1080H45DV 1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 86 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.95 / +38.0%

ENERGY STAR certification places American HPHE10280H045DVCTA-1** at 3.45 UEF (#563 of 706; -0.25 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: American HPHE10280H045DVCTA-1** stands +0.95 UEF (+38.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for American HPHE10280H045DVCTA-1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.
State electric sensitivity for American HPHE10280H045DVCTA-1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith HP1080H45DV 1** (3.45 UEF, at parity) and Lochinvar HPA082KD 1** (3.45 UEF, at parity) bracket American HPHE10280H045DVCTA-1**.
How Do American HPHE10280H045DVCTA-1** Specs Compare to Hybrid/Electric Heat Pump Medians?
American HPHE10280H045DVCTA-1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408858 |
| Model Number | HPHE10280H045DVCTA-1** | Draw pattern: High-Usage | HPHE10280H045DVCTA-1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,387 kWh/yr | +315 kWh/yr vs. 1,072 kWh/yr median | Est. $252/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 233% | -196.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
What Does HPHE10280H045DVCTA-1** Cost to Operate Across State Electricity Rates?
At 1,387 kWh/yr, American HPHE10280H045DVCTA-1** runs roughly $252/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $252/yr | $2,519 | $6,926 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $654/yr | $6,544 | $17,994 |
| California | 29.75 ¢/kWh ($0.2975) | $413/yr | $4,126 | $11,347 |
| Texas | 15.91 ¢/kWh ($0.1591) | $221/yr | $2,207 | $6,068 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $203/yr | $2,029 | $5,580 |
Are There Active CPSC Safety Recalls for American Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with American; match your serial plate before repair. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match HPHE10280H045DVCTA-1** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to American HPHE10280H045DVCTA-1** by storage capacity and 3.45 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HP1080H45DV 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| Lochinvar HPA082KD 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| State HPX-80-DHPTCTA 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| A. O. Smith HP1080H45DVCTA-1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
When Should Homeowners Skip American HPHE10280H045DVCTA-1** (Hybrid/Electric Heat Pump)?
Check American HPHE10280H045DVCTA-1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.95 / +38.0% status—against typical residential installations.
Key Limitations & Exclusions
- American HPHE10280H045DVCTA-1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPHE10280H045DVCTA-1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About American HPHE10280H045DVCTA-1**?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will American HPHE10280H045DVCTA-1** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.45 UEF, American HPHE10280H045DVCTA-1** shows Pass: +0.95 / +38.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HP1080H45DV 1**.
Will American HPHE10280H045DVCTA-1** fit through a standard utility door and 72-inch basement ceiling?
Measuring 69 in. tall by 27 in. diameter, American HPHE10280H045DVCTA-1** notes: verify 72 in. vertical headroom; tight at 28 in. door (27" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support American HPHE10280H045DVCTA-1** during replacement?
Electrical specs for American HPHE10280H045DVCTA-1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for American HPHE10280H045DVCTA-1**?
At 18.16 cents/kWh national residential pricing, American HPHE10280H045DVCTA-1**'s 1,387 kWh/yr draw equals roughly $252 annually or $2,520 across a 10-year horizon (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii).
When is American HPHE10280H045DVCTA-1** a poor fit for a residential replacement?
Avoid placing American HPHE10280H045DVCTA-1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does American HPHE10280H045DVCTA-1** deliver?
With 86 gal FHR (+14 gal vs. 72 gal median), American HPHE10280H045DVCTA-1** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on American HPHE10280H045DVCTA-1**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does American HPHE10280H045DVCTA-1** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPHE10280H045DVCTA-1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1080H45DV 1** (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)