Skip to main content
ENERGY STAR water heater model · PD 2408866

Lochinvar HPA082KD 1** Water Heater Specifications (3.45 UEF)

Certified at 3.45 UEF across its 82-gallon nominal tank, 86 gal First Hour Rating, Lochinvar HPA082KD 1** (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 2408866). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1080H45DV 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
86 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPA082KD 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Lochinvar HPA082KD 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPA082KD 1** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.45 UEF, Lochinvar HPA082KD 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).

Lochinvar HPA082KD 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for Lochinvar HPA082KD 1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar HPA082KD 1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Lochinvar HPA082KD 1** include A. O. Smith HP1080H45DV 1** (3.45 UEF, at parity) alongside American HPHE10280H045DVCTA-1** (3.45 UEF, at parity).

How Do Lochinvar HPA082KD 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

Lochinvar HPA082KD 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 2408866
Model NumberHPA082KD 1**Draw pattern: High-UsageHPA082KD 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal+14 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,387 kWh/yr+315 kWh/yr vs. 1,072 kWh/yr medianEst. $252/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency233%-196.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

What Does HPA082KD 1** Cost to Operate Across State Electricity Rates?

At 1,387 kWh/yr, Lochinvar HPA082KD 1** runs roughly $252/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,387 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$252.00/yrHawaii$654.00/yrCalifornia$413.00/yrTexas$221.00/yrWashington$203.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $252/yr $2,519 $6,926
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $654/yr $6,544 $17,994
California 29.75 ¢/kWh ($0.2975) $413/yr $4,126 $11,347
Texas 15.91 ¢/kWh ($0.1591) $221/yr $2,207 $6,068
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $203/yr $2,029 $5,580
Estimated electricity spend (1,387 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Lochinvar Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 1 brand-level recall notice associated with Lochinvar; match your serial plate before repair. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match HPA082KD 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Lochinvar HPA082KD 1** by storage capacity and 3.45 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HP1080H45DV 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
American HPHE10280H045DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
State HPX-80-DHPTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
A. O. Smith HP1080H45DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387

Which Home Setups Are NOT a Fit for Lochinvar HPA082KD 1**?

Comparing Lochinvar HPA082KD 1** against A. O. Smith HP1080H45DV 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Lochinvar HPA082KD 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar HPA082KD 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPA082KD 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HP1080H45DV 1** footprint.

What Are the Key Questions About Lochinvar HPA082KD 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Lochinvar HPA082KD 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lochinvar HPA082KD 1** logs 3.45 UEF (Pass: +0.95 / +38.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Lochinvar HPA082KD 1**?

With a 69 in. height and 27 in. diameter, Lochinvar HPA082KD 1** fits spaces matching: verify 72 in. vertical headroom; tight at 28 in. door (27" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Lochinvar HPA082KD 1**?

Powered via 240V at 22A max, Lochinvar HPA082KD 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Lochinvar HPA082KD 1**?

Annual electric spend for Lochinvar HPA082KD 1** (1,387 kWh/yr) averages $252/yr nationwide (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Lochinvar HPA082KD 1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lochinvar HPA082KD 1**.

Is Lochinvar HPA082KD 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Lochinvar HPA082KD 1** at 86 gal First Hour Rating (+14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Lochinvar have active CPSC SaferProducts notices affecting HPA082KD 1**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches Lochinvar HPA082KD 1** (3.45 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lochinvar HPA082KD 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1080H45DV 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks