American HPHE10280H045DVDR 1** Water Heater Specifications (3.45 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, American HPHE10280H045DVDR 1** (Electric) achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 86 gal First Hour Rating (rank #563 of 706, PD 2408859) and verifies as Pass: +0.95 / +38.0% for 2029 DOE floors. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1080H45DV 1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 86 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.95 / +38.0%

American HPHE10280H045DVDR 1** records 3.45 UEF efficiency, putting it #563 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: American HPHE10280H045DVDR 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for American HPHE10280H045DVDR 1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.
State electric sensitivity for American HPHE10280H045DVDR 1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside American HPHE10280H045DVDR 1** (3.45 UEF) are A. O. Smith HP1080H45DV 1** (3.45 UEF, at parity) and Lochinvar HPA082KD 1** (3.45 UEF, at parity).
Where Does American HPHE10280H045DVDR 1** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, American HPHE10280H045DVDR 1** holds #563 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408859 |
| Model Number | HPHE10280H045DVDR 1** | Draw pattern: High-Usage | HPHE10280H045DVDR 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,387 kWh/yr | +315 kWh/yr vs. 1,072 kWh/yr median | Est. $252/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 233% | -196.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
How Much Electricity Does HPHE10280H045DVDR 1** Use in Different States?
Estimated at $252/yr nationally (1,387 kWh/yr), 10-year utility spending for American HPHE10280H045DVDR 1** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $252/yr | $2,519 | $6,926 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $654/yr | $6,544 | $17,994 |
| California | 29.75 ¢/kWh ($0.2975) | $413/yr | $4,126 | $11,347 |
| Texas | 15.91 ¢/kWh ($0.1591) | $221/yr | $2,207 | $6,068 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $203/yr | $2,029 | $5,580 |
Does CPSC Flag Any Safety Notices on American Units?
Checking 2026-11-23 SaferProducts data shows 2 notices mentioning American; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPHE10280H045DVDR 1**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to American HPHE10280H045DVDR 1**'s gallon capacity and 3.45 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HP1080H45DV 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| Lochinvar HPA082KD 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| State HPX-80-DHPTCTA 1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
| A. O. Smith HP1080H45DVCTA-1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
What Are the Limitations of American HPHE10280H045DVDR 1** and Who Should Not Install It?
Before ordering American HPHE10280H045DVDR 1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- American HPHE10280H045DVDR 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPHE10280H045DVDR 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for American HPHE10280H045DVDR 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does American HPHE10280H045DVDR 1** pass the May 6, 2029 federal DOE efficiency rule?
American HPHE10280H045DVDR 1** carries a verified 3.45 UEF rating (Pass: +0.95 / +38.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does American HPHE10280H045DVDR 1** need?
American HPHE10280H045DVDR 1** stands 69 in. high with a 27 in. diameter; verify 72 in. vertical headroom; tight at 28 in. door (27" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does American HPHE10280H045DVDR 1** require?
American HPHE10280H045DVDR 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does American HPHE10280H045DVDR 1** cost per year to run?
Rated at 1,387 kWh/yr, American HPHE10280H045DVDR 1** costs about $252/yr ($2,520 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii).
Who should NOT install American HPHE10280H045DVDR 1**, and what are its limits?
American HPHE10280H045DVDR 1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can American HPHE10280H045DVDR 1** serve at peak demand?
American HPHE10280H045DVDR 1** achieves a 86 gal First Hour Rating (+14 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for American HPHE10280H045DVDR 1**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to American HPHE10280H045DVDR 1**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1080H45DV 1** (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)