Skip to main content
ENERGY STAR water heater model · PD 2408868

American HPHE10280H045DVN 1** Water Heater Specifications (3.45 UEF)

With PD 2408868 certification, American HPHE10280H045DVN 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 86 gal First Hour Rating, standing #563 of 706 across 706 peers with Pass: +0.95 / +38.0% for May 6, 2029. Rated annual electricity draw of 1,387 kWh/yr equates to roughly $252/yr ($2,519 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1080H45DV 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
86 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPHE10280H045DVN 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50American HPHE10280H045DVN 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPHE10280H045DVN 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places American HPHE10280H045DVN 1** at 3.45 UEF (#563 of 706; -0.25 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: American HPHE10280H045DVN 1** stands +0.95 UEF (+38.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,387 kWh/yr for American HPHE10280H045DVN 1** runs ~$252/yr vs. ~$945/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPHE10280H045DVN 1**: 10-year operating spend spans $2,029 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,544 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HP1080H45DV 1** (3.45 UEF, at parity) and Lochinvar HPA082KD 1** (3.45 UEF, at parity) bracket American HPHE10280H045DVN 1**.

What Physical and Thermal Ratings Define American HPHE10280H045DVN 1**?

Positioning at #563 of 706 out of 706 Hybrid/Electric Heat Pump peers, American HPHE10280H045DVN 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408868
Model NumberHPHE10280H045DVN 1**Draw pattern: High-UsageHPHE10280H045DVN 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal+14 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,387 kWh/yr+315 kWh/yr vs. 1,072 kWh/yr medianEst. $252/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency233%-196.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

Why Do State Utility Rates Shift HPHE10280H045DVN 1** Running Costs?

Consuming 1,387 kWh annually puts American HPHE10280H045DVN 1** near $252/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,387 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$252.00/yrHawaii$654.00/yrCalifornia$413.00/yrTexas$221.00/yrWashington$203.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $252/yr $2,519 $6,926
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $654/yr $6,544 $17,994
California 29.75 ¢/kWh ($0.2975) $413/yr $4,126 $11,347
Texas 15.91 ¢/kWh ($0.1591) $221/yr $2,207 $6,068
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $203/yr $2,029 $5,580
Estimated electricity spend (1,387 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any American Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to American HPHE10280H045DVN 1**?

Homeowners cross-shopping American HPHE10280H045DVN 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HP1080H45DV 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
Lochinvar HPA082KD 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
RELIANCE WATER HEATERS 10-80-DHPHTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
State HPX-80-DHPTCTA 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387
A. O. Smith HP1080H45DVCTA-1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387

What Are the Limitations of American HPHE10280H045DVN 1** and Who Should Not Install It?

Before ordering American HPHE10280H045DVN 1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • American HPHE10280H045DVN 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPHE10280H045DVN 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPHE10280H045DVN 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HP1080H45DV 1** footprint.

Sizing, Efficiency & Recall Answers for American HPHE10280H045DVN 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does American HPHE10280H045DVN 1** pass the May 6, 2029 federal DOE efficiency rule?

American HPHE10280H045DVN 1** carries a verified 3.45 UEF rating (Pass: +0.95 / +38.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does American HPHE10280H045DVN 1** need?

American HPHE10280H045DVN 1** stands 69 in. high with a 27 in. diameter; verify 72 in. vertical headroom; tight at 28 in. door (27" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does American HPHE10280H045DVN 1** require?

American HPHE10280H045DVN 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does American HPHE10280H045DVN 1** cost per year to run?

Rated at 1,387 kWh/yr, American HPHE10280H045DVN 1** costs about $252/yr ($2,520 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $203/yr in Washington hydro tiers up to $654/yr in Hawaii).

Who should NOT install American HPHE10280H045DVN 1**, and what are its limits?

American HPHE10280H045DVN 1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can American HPHE10280H045DVN 1** serve at peak demand?

American HPHE10280H045DVN 1** achieves a 86 gal First Hour Rating (+14 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for American HPHE10280H045DVN 1**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to American HPHE10280H045DVN 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1080H45DV 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks