American HPHE6266H045DV 1** Water Heater Specifications (3.42 UEF)

With PD 2408903 certification, American HPHE6266H045DV 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.42 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating, standing #624 of 706 across 706 peers with Pass: +0.92 / +36.8% for May 6, 2029. Rated annual electricity draw of 1,391 kWh/yr equates to roughly $253/yr ($2,526 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-66 1** (3.42 UEF).

Uniform Energy Factor
3.42 UEF
Cohort UEF Rank
#624 of 706
First Hour Rating
79 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.92 / +36.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPHE6266H045DV 1** at 3.42 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50American HPHE6266H045DV 1**: 3.42
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPHE6266H045DV 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places American HPHE6266H045DV 1** at 3.42 UEF (#624 of 706; -0.28 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: American HPHE6266H045DV 1** stands +0.92 UEF (+36.8%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,391 kWh/yr for American HPHE6266H045DV 1** runs ~$253/yr vs. ~$939/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPHE6266H045DV 1**: 10-year operating spend spans $2,035 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,563 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith FPTU-66 1** (3.42 UEF, at parity) and RELIANCE WATER HEATERS 6-66-DHPHT 1** (3.42 UEF, at parity) bracket American HPHE6266H045DV 1**.

How Complete Are the Certified Metrics for American HPHE6266H045DV 1**?

Standing at #624 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, American HPHE6266H045DV 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408903
Model NumberHPHE6266H045DV 1**Draw pattern: High-UsageHPHE6266H045DV 1**
Uniform Energy Factor (UEF)3.42-0.28 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)79 gal+7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,391 kWh/yr+319 kWh/yr vs. 1,072 kWh/yr medianEst. $253/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency265%-164.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States

What Is the Projected Utility Bill for HPHE6266H045DV 1** by State?

At 1,391 kWh/yr, American HPHE6266H045DV 1** averages about $253/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,391 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$253.00/yrHawaii$656.00/yrCalifornia$414.00/yrTexas$221.00/yrWashington$204.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $253/yr $2,526 $6,864
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $656/yr $6,563 $17,834
California 29.75 ¢/kWh ($0.2975) $414/yr $4,138 $11,246
Texas 15.91 ¢/kWh ($0.1591) $221/yr $2,213 $6,014
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $204/yr $2,035 $5,530
Estimated electricity spend (1,391 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are American Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to HPHE6266H045DV 1**?

Ordered by minimal capacity and UEF spread relative to American HPHE6266H045DV 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith FPTU-66 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
RELIANCE WATER HEATERS 6-66-DHPHT 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
State HP6-66-DHPT 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
U.S. Craftmaster HPHE2F66HD045VU 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
A. O. Smith HPTU-66CTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (+0.03) 1,381

When Should Homeowners Skip American HPHE6266H045DV 1** (Hybrid/Electric Heat Pump)?

Check American HPHE6266H045DV 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.92 / +36.8% status—against typical residential installations.

Key Limitations & Exclusions

  • American HPHE6266H045DV 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPHE6266H045DV 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPHE6266H045DV 1** Strong Fit — 3.42 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith FPTU-66 1** footprint.

Practical Specs & Code Questions for American HPHE6266H045DV 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will American HPHE6266H045DV 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.42 UEF, American HPHE6266H045DV 1** shows Pass: +0.92 / +36.8% relative to May 6, 2029 federal DOE limits while placing #624 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith FPTU-66 1**.

Will American HPHE6266H045DV 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, American HPHE6266H045DV 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support American HPHE6266H045DV 1** during replacement?

Electrical specs for American HPHE6266H045DV 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for American HPHE6266H045DV 1**?

At 18.16 cents/kWh national residential pricing, American HPHE6266H045DV 1**'s 1,391 kWh/yr draw equals roughly $253 annually or $2,530 across a 10-year horizon (ranging from $204/yr in Washington hydro tiers up to $656/yr in Hawaii).

When is American HPHE6266H045DV 1** a poor fit for a residential replacement?

Avoid placing American HPHE6266H045DV 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does American HPHE6266H045DV 1** deliver?

With 79 gal FHR (+7 gal vs. 72 gal median), American HPHE6266H045DV 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on American HPHE6266H045DV 1**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does American HPHE6266H045DV 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPHE6266H045DV 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-66 1** (3.42 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks