American HPHE6266H045DV 1** Water Heater Specifications (3.42 UEF)
With PD 2408903 certification, American HPHE6266H045DV 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.42 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating, standing #624 of 706 across 706 peers with Pass: +0.92 / +36.8% for May 6, 2029. Rated annual electricity draw of 1,391 kWh/yr equates to roughly $253/yr ($2,526 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-66 1** (3.42 UEF).
- Uniform Energy Factor
- 3.42 UEF
- Cohort UEF Rank
- #624 of 706
- First Hour Rating
- 79 gal
- Storage Volume
- 67 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.92 / +36.8%

ENERGY STAR certification places American HPHE6266H045DV 1** at 3.42 UEF (#624 of 706; -0.28 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: American HPHE6266H045DV 1** stands +0.92 UEF (+36.8%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,391 kWh/yr for American HPHE6266H045DV 1** runs ~$253/yr vs. ~$939/yr for a 0.92 UEF electric tank.
State electric sensitivity for American HPHE6266H045DV 1**: 10-year operating spend spans $2,035 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,563 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith FPTU-66 1** (3.42 UEF, at parity) and RELIANCE WATER HEATERS 6-66-DHPHT 1** (3.42 UEF, at parity) bracket American HPHE6266H045DV 1**.
How Complete Are the Certified Metrics for American HPHE6266H045DV 1**?
Standing at #624 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, American HPHE6266H045DV 1** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408903 |
| Model Number | HPHE6266H045DV 1** | Draw pattern: High-Usage | HPHE6266H045DV 1** |
| Uniform Energy Factor (UEF) | 3.42 | -0.28 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 79 gal | +7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,391 kWh/yr | +319 kWh/yr vs. 1,072 kWh/yr median | Est. $253/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 265% | -164.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |
What Is the Projected Utility Bill for HPHE6266H045DV 1** by State?
At 1,391 kWh/yr, American HPHE6266H045DV 1** averages about $253/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $253/yr | $2,526 | $6,864 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $656/yr | $6,563 | $17,834 |
| California | 29.75 ¢/kWh ($0.2975) | $414/yr | $4,138 | $11,246 |
| Texas | 15.91 ¢/kWh ($0.1591) | $221/yr | $2,213 | $6,014 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $204/yr | $2,035 | $5,530 |
Are American Models Affected by Current CPSC Notices?
Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to HPHE6266H045DV 1**?
Ordered by minimal capacity and UEF spread relative to American HPHE6266H045DV 1**, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith FPTU-66 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| RELIANCE WATER HEATERS 6-66-DHPHT 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| State HP6-66-DHPT 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| U.S. Craftmaster HPHE2F66HD045VU 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| A. O. Smith HPTU-66CTA 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (+0.03) | 1,381 |
When Should Homeowners Skip American HPHE6266H045DV 1** (Hybrid/Electric Heat Pump)?
Check American HPHE6266H045DV 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.92 / +36.8% status—against typical residential installations.
Key Limitations & Exclusions
- American HPHE6266H045DV 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPHE6266H045DV 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for American HPHE6266H045DV 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will American HPHE6266H045DV 1** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.42 UEF, American HPHE6266H045DV 1** shows Pass: +0.92 / +36.8% relative to May 6, 2029 federal DOE limits while placing #624 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith FPTU-66 1**.
Will American HPHE6266H045DV 1** fit through a standard utility door and 72-inch basement ceiling?
Measuring 61 in. tall by 23 in. diameter, American HPHE6266H045DV 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support American HPHE6266H045DV 1** during replacement?
Electrical specs for American HPHE6266H045DV 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for American HPHE6266H045DV 1**?
At 18.16 cents/kWh national residential pricing, American HPHE6266H045DV 1**'s 1,391 kWh/yr draw equals roughly $253 annually or $2,530 across a 10-year horizon (ranging from $204/yr in Washington hydro tiers up to $656/yr in Hawaii).
When is American HPHE6266H045DV 1** a poor fit for a residential replacement?
Avoid placing American HPHE6266H045DV 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does American HPHE6266H045DV 1** deliver?
With 79 gal FHR (+7 gal vs. 72 gal median), American HPHE6266H045DV 1** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on American HPHE6266H045DV 1**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does American HPHE6266H045DV 1** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American HPHE6266H045DV 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-66 1** (3.42 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)