Skip to main content
ENERGY STAR water heater model · PD 2408902

State HP6-66-DHPT 1** Water Heater Specifications (3.42 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, State HP6-66-DHPT 1** achieves a certified 3.42 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating and ranks #624 of 706 in its 706-model cohort (PD 2408902), recording Pass: +0.92 / +36.8% under 2029 DOE rules. Rated annual electricity draw of 1,391 kWh/yr equates to roughly $253/yr ($2,526 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-66 1** (3.42 UEF).

Uniform Energy Factor
3.42 UEF
Cohort UEF Rank
#624 of 706
First Hour Rating
79 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.92 / +36.8%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State HP6-66-DHPT 1** at 3.42 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State HP6-66-DHPT 1**: 3.42
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HP6-66-DHPT 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, State HP6-66-DHPT 1** logs 3.42 UEF and ranks #624 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), State HP6-66-DHPT 1** holds a +0.92 UEF (+36.8%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,391 kWh/yr for State HP6-66-DHPT 1** runs ~$253/yr vs. ~$939/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HP6-66-DHPT 1**: 10-year operating spend spans $2,035 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,563 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping State HP6-66-DHPT 1** (3.42 UEF)? Check A. O. Smith FPTU-66 1** (3.42 UEF, at parity) and American HPHE6266H045DV 1** (3.42 UEF, at parity).

Where Does State HP6-66-DHPT 1** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, State HP6-66-DHPT 1** holds #624 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 2408902
Model NumberHP6-66-DHPT 1**Draw pattern: High-UsageHP6-66-DHPT 1**
Uniform Energy Factor (UEF)3.42-0.28 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)79 gal+7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,391 kWh/yr+319 kWh/yr vs. 1,072 kWh/yr medianEst. $253/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency265%-164.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States

How Much Electricity Does HP6-66-DHPT 1** Use in Different States?

Estimated at $253/yr nationally (1,391 kWh/yr), 10-year utility spending for State HP6-66-DHPT 1** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (1,391 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$253.00/yrHawaii$656.00/yrCalifornia$414.00/yrTexas$221.00/yrWashington$204.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $253/yr $2,526 $6,864
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $656/yr $6,563 $17,834
California 29.75 ¢/kWh ($0.2975) $414/yr $4,138 $11,246
Texas 15.91 ¢/kWh ($0.1591) $221/yr $2,213 $6,014
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $204/yr $2,035 $5,530
Estimated electricity spend (1,391 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on State Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning State; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HP6-66-DHPT 1**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to State HP6-66-DHPT 1**'s gallon capacity and 3.42 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith FPTU-66 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
American HPHE6266H045DV 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
RELIANCE WATER HEATERS 6-66-DHPHT 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
U.S. Craftmaster HPHE2F66HD045VU 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.42 (at parity) 1,391
A. O. Smith HPTU-66CTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (+0.03) 1,381

Which Home Setups Are NOT a Fit for State HP6-66-DHPT 1**?

Comparing State HP6-66-DHPT 1** against A. O. Smith FPTU-66 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • State HP6-66-DHPT 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State HP6-66-DHPT 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State HP6-66-DHPT 1** Strong Fit — 3.42 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith FPTU-66 1** footprint.

Common Homeowner Questions for State HP6-66-DHPT 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does State HP6-66-DHPT 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; State HP6-66-DHPT 1** logs 3.42 UEF (Pass: +0.92 / +36.8%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing State HP6-66-DHPT 1**?

With a 61 in. height and 23 in. diameter, State HP6-66-DHPT 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits State HP6-66-DHPT 1**?

Powered via 240V at 22A max, State HP6-66-DHPT 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for State HP6-66-DHPT 1**?

Annual electric spend for State HP6-66-DHPT 1** (1,391 kWh/yr) averages $253/yr nationwide (ranging from $204/yr in Washington hydro tiers up to $656/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing State HP6-66-DHPT 1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on State HP6-66-DHPT 1**.

Is State HP6-66-DHPT 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies State HP6-66-DHPT 1** at 79 gal First Hour Rating (+7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does State have active CPSC SaferProducts notices affecting HP6-66-DHPT 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches State HP6-66-DHPT 1** (3.42 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for State HP6-66-DHPT 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-66 1** (3.42 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks