Skip to main content
ENERGY STAR water heater model · PD 2408887

American HPHE6280H045DV 1** Water Heater Specifications (3.45 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, American HPHE6280H045DV 1** achieves a certified 3.45 UEF rating across its 82-gallon nominal tank, 84 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408887), recording Pass: +0.95 / +38.0% under 2029 DOE rules. Rated annual electricity draw of 1,396 kWh/yr equates to roughly $254/yr ($2,535 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-80 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
84 gal
Storage Volume
82 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPHE6280H045DV 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50American HPHE6280H045DV 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPHE6280H045DV 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, American HPHE6280H045DV 1** logs 3.45 UEF and ranks #563 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), American HPHE6280H045DV 1** holds a +0.95 UEF (+38.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,396 kWh/yr for American HPHE6280H045DV 1** runs ~$254/yr vs. ~$951/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPHE6280H045DV 1**: 10-year operating spend spans $2,042 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping American HPHE6280H045DV 1** (3.45 UEF)? Check A. O. Smith FPTU-80 1** (3.45 UEF, at parity) and RELIANCE WATER HEATERS 6-80-DHPHT 1** (3.45 UEF, at parity).

How Do American HPHE6280H045DV 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

American HPHE6280H045DV 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408887
Model NumberHPHE6280H045DV 1**Draw pattern: High-UsageHPHE6280H045DV 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)84 gal+12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,396 kWh/yr+324 kWh/yr vs. 1,072 kWh/yr medianEst. $254/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency233%-196.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States

What Does HPHE6280H045DV 1** Cost to Operate Across State Electricity Rates?

At 1,396 kWh/yr, American HPHE6280H045DV 1** runs roughly $254/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,396 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$254.00/yrHawaii$659.00/yrCalifornia$415.00/yrTexas$222.00/yrWashington$204.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $254/yr $2,535 $6,972
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $659/yr $6,586 $18,112
California 29.75 ¢/kWh ($0.2975) $415/yr $4,153 $11,421
Texas 15.91 ¢/kWh ($0.1591) $222/yr $2,221 $6,108
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $204/yr $2,042 $5,616
Estimated electricity spend (1,396 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for American Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with American; match your serial plate before repair. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match HPHE6280H045DV 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to American HPHE6280H045DV 1** by storage capacity and 3.45 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith FPTU-80 1** Hybrid/Electric Heat Pump 82 gal 84 gal 3.45 (at parity) 1,396
RELIANCE WATER HEATERS 6-80-DHPHT 1** Hybrid/Electric Heat Pump 82 gal 84 gal 3.45 (at parity) 1,396
State HP6-80-DHPT 1** Hybrid/Electric Heat Pump 82 gal 84 gal 3.45 (at parity) 1,396
U.S. Craftmaster HPHE2F80HD045VU 1** Hybrid/Electric Heat Pump 82 gal 84 gal 3.45 (at parity) 1,396
A. O. Smith HP1080H45DV 1** Hybrid/Electric Heat Pump 82 gal 86 gal 3.45 (at parity) 1,387

Who Is American HPHE6280H045DV 1** Best For — and When Should You Pick A. O. Smith FPTU-80 1**?

Evaluate whether American HPHE6280H045DV 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • American HPHE6280H045DV 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPHE6280H045DV 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPHE6280H045DV 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith FPTU-80 1** footprint.

What Are the Key Questions About American HPHE6280H045DV 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does American HPHE6280H045DV 1** (3.45 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American HPHE6280H045DV 1** records 3.45 UEF (Pass: +0.95 / +38.0%), placing #563 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does American HPHE6280H045DV 1** fit inside a tight hallway closet or low-headroom utility room?

American HPHE6280H045DV 1** requires room for its 69 in. vertical shell and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern American HPHE6280H045DV 1**?

For American HPHE6280H045DV 1**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for American HPHE6280H045DV 1**?

Using 1,396 kWh/yr, American HPHE6280H045DV 1** generates an estimated $254/yr electric bill at 18.16 cents/kWh (ranging from $204/yr in Washington hydro tiers up to $659/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of American HPHE6280H045DV 1** (3.45 UEF)?

American HPHE6280H045DV 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith FPTU-80 1**.

What hot-water delivery rating governs American HPHE6280H045DV 1**?

Rated for 84 gal FHR (+12 gal vs. 72 gal median), American HPHE6280H045DV 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen American HPHE6280H045DV 1** for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to American HPHE6280H045DV 1** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-80 1** (3.45 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks