A. O. Smith FPTU-80 1** Water Heater Specifications (3.45 UEF)
Certified at 3.45 UEF across its 82-gallon nominal tank, 84 gal First Hour Rating, A. O. Smith FPTU-80 1** (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 2408886). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,396 kWh/yr equates to roughly $254/yr ($2,535 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE6280H045DV 1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 84 gal
- Storage Volume
- 82 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.95 / +38.0%

Tested at 3.45 UEF, A. O. Smith FPTU-80 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).
A. O. Smith FPTU-80 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,396 kWh/yr for A. O. Smith FPTU-80 1** runs ~$254/yr vs. ~$951/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith FPTU-80 1**: 10-year operating spend spans $2,042 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,586 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to A. O. Smith FPTU-80 1** include American HPHE6280H045DV 1** (3.45 UEF, at parity) alongside RELIANCE WATER HEATERS 6-80-DHPHT 1** (3.45 UEF, at parity).
How Do A. O. Smith FPTU-80 1** Specs Compare to Hybrid/Electric Heat Pump Medians?
A. O. Smith FPTU-80 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2408886 |
| Model Number | FPTU-80 1** | Draw pattern: High-Usage | FPTU-80 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 84 gal | +12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,396 kWh/yr | +324 kWh/yr vs. 1,072 kWh/yr median | Est. $254/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 233% | -196.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 69" H x 27" D | Verify 72 in. vertical headroom; tight at 28 in. door (27" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |
What Does FPTU-80 1** Cost to Operate Across State Electricity Rates?
At 1,396 kWh/yr, A. O. Smith FPTU-80 1** runs roughly $254/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $254/yr | $2,535 | $6,972 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $659/yr | $6,586 | $18,112 |
| California | 29.75 ¢/kWh ($0.2975) | $415/yr | $4,153 | $11,421 |
| Texas | 15.91 ¢/kWh ($0.1591) | $222/yr | $2,221 | $6,108 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $204/yr | $2,042 | $5,616 |
Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match FPTU-80 1** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith FPTU-80 1** by storage capacity and 3.45 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPHE6280H045DV 1** | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| RELIANCE WATER HEATERS 6-80-DHPHT 1** | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| State HP6-80-DHPT 1** | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| U.S. Craftmaster HPHE2F80HD045VU 1** | Hybrid/Electric Heat Pump | 82 gal | 84 gal | 3.45 (at parity) | 1,396 |
| American HPHE10280H045DVCTA-1** | Hybrid/Electric Heat Pump | 82 gal | 86 gal | 3.45 (at parity) | 1,387 |
What Installation Caveats Apply Before Buying A. O. Smith FPTU-80 1**?
Even high-UEF units like A. O. Smith FPTU-80 1** (3.45 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- A. O. Smith FPTU-80 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith FPTU-80 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About A. O. Smith FPTU-80 1**?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is A. O. Smith FPTU-80 1** eligible for continued manufacture past May 6, 2029?
At 3.45 UEF, A. O. Smith FPTU-80 1** achieves Pass: +0.95 / +38.0% for the 2029 DOE standard and stands #563 of 706 against American HPHE6280H045DV 1** and RELIANCE WATER HEATERS 6-80-DHPHT 1**.
How tall and wide is A. O. Smith FPTU-80 1**, and what service clearance is needed?
Physical dimensions for A. O. Smith FPTU-80 1** are 69 in. height and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)); verify stair turns and drain pan width before delivery.
Will A. O. Smith FPTU-80 1** require upgrading household electrical panels or gas piping?
A. O. Smith FPTU-80 1** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is A. O. Smith FPTU-80 1** economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $254/yr ($2,540 over 10 years) to power A. O. Smith FPTU-80 1** at 1,396 kWh/yr under the 18.16 cents/kWh US average (ranging from $204/yr in Washington hydro tiers up to $659/yr in Hawaii).
Which installation bottlenecks limit A. O. Smith FPTU-80 1**?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith FPTU-80 1** drops into resistance mode more often.
How does A. O. Smith FPTU-80 1** handle simultaneous showers and laundry?
Delivering 84 gal in the first hour (+12 gal vs. 72 gal median), A. O. Smith FPTU-80 1** combines 82 gal tank storage with rapid burner/element recovery.
How long is the warranty on A. O. Smith FPTU-80 1** and how do you decode its serial?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
How do 2026 post-OBBBA rebates affect buying A. O. Smith FPTU-80 1**?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPHE6280H045DV 1** (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)