American MHPCO-45 1**+MXST-50T 1** Water Heater Specifications (3.52 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, American MHPCO-45 1**+MXST-50T 1** (Electric) achieves a certified 3.52 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating (rank #441 of 706, PD 4529454) and verifies as Pass: +1.22 / +53.0% for 2029 DOE floors. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American MHPCO-45 1**+MXST-50T 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30American MHPCO-45 1**+MXST-50T 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American MHPCO-45 1**+MXST-50T 1** relative to the cohort median.
Efficiency comparison & rule summary

American MHPCO-45 1**+MXST-50T 1** records 3.52 UEF efficiency, putting it #441 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: American MHPCO-45 1**+MXST-50T 1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.22 UEF (+53.0%). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for American MHPCO-45 1**+MXST-50T 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for American MHPCO-45 1**+MXST-50T 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside American MHPCO-45 1**+MXST-50T 1** (3.52 UEF) are A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF, at parity) and Giant GHPCO-45 1**+GXST-50T 1** (3.52 UEF, at parity).

Which Specs Set American MHPCO-45 1**+MXST-50T 1** Apart From Cohort Averages?

Ranked #441 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, American MHPCO-45 1**+MXST-50T 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 4529454
Model NumberMHPCO-45 1**+MXST-50T 1**Draw pattern: Medium-UsageMHPCO-45 1**+MXST-50T 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency413%-16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57" H x 16" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

How Do Regional kWh Prices Impact MHPCO-45 1**+MXST-50T 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, American MHPCO-45 1**+MXST-50T 1**'s 923 kWh/yr draw translates to roughly $168/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should American Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to American; verify whether your MHPCO-45 1**+MXST-50T 1** production run falls inside affected ranges. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
Giant GHPCO-45 1**+GXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
John Wood JWHPCO-45 1**+JWXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50TTTP 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923

Who Is American MHPCO-45 1**+MXST-50T 1** Best For — and When Should You Pick A. O. Smith HPACO-45 1**+AXST-50T 1**?

Evaluate whether American MHPCO-45 1**+MXST-50T 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • American MHPCO-45 1**+MXST-50T 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American MHPCO-45 1**+MXST-50T 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American MHPCO-45 1**+MXST-50T 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50T 1** footprint.

Frequently Asked Technical Questions: American MHPCO-45 1**+MXST-50T 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does American MHPCO-45 1**+MXST-50T 1** (3.52 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American MHPCO-45 1**+MXST-50T 1** records 3.52 UEF (Pass: +1.22 / +53.0%), placing #441 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does American MHPCO-45 1**+MXST-50T 1** fit inside a tight hallway closet or low-headroom utility room?

American MHPCO-45 1**+MXST-50T 1** requires room for its 57 in. vertical shell and 16 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern American MHPCO-45 1**+MXST-50T 1**?

For American MHPCO-45 1**+MXST-50T 1**, plan a 240V circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for American MHPCO-45 1**+MXST-50T 1**?

Using 923 kWh/yr, American MHPCO-45 1**+MXST-50T 1** generates an estimated $168/yr electric bill at 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of American MHPCO-45 1**+MXST-50T 1** (3.52 UEF)?

American MHPCO-45 1**+MXST-50T 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPACO-45 1**+AXST-50T 1**.

What hot-water delivery rating governs American MHPCO-45 1**+MXST-50T 1**?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), American MHPCO-45 1**+MXST-50T 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen American MHPCO-45 1**+MXST-50T 1** for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to American MHPCO-45 1**+MXST-50T 1** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)