Skip to main content
ENERGY STAR water heater model · PD 4529472

A. O. Smith HPACO-45 1**+AXST-50T 1** Water Heater Specifications (3.52 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith HPACO-45 1**+AXST-50T 1** achieves a certified 3.52 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating and ranks #441 of 706 in its 706-model cohort (PD 4529472), recording Pass: +1.22 / +53.0% under 2029 DOE rules. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American MHPCO-45 1**+MXST-50T 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPACO-45 1**+AXST-50T 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30A. O. Smith HPACO-45 1**+AXST-50T 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPACO-45 1**+AXST-50T 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, A. O. Smith HPACO-45 1**+AXST-50T 1** logs 3.52 UEF and ranks #441 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), A. O. Smith HPACO-45 1**+AXST-50T 1** holds a +1.22 UEF (+53.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for A. O. Smith HPACO-45 1**+AXST-50T 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPACO-45 1**+AXST-50T 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF)? Check American MHPCO-45 1**+MXST-50T 1** (3.52 UEF, at parity) and Giant GHPCO-45 1**+GXST-50T 1** (3.52 UEF, at parity).

Where Does A. O. Smith HPACO-45 1**+AXST-50T 1** Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, A. O. Smith HPACO-45 1**+AXST-50T 1** holds #441 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4529472
Model NumberHPACO-45 1**+AXST-50T 1**Draw pattern: Medium-UsageHPACO-45 1**+AXST-50T 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency413%-16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57" H x 16" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States, Canada

How Much Electricity Does HPACO-45 1**+AXST-50T 1** Use in Different States?

Estimated at $168/yr nationally (923 kWh/yr), 10-year utility spending for A. O. Smith HPACO-45 1**+AXST-50T 1** shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on A. O. Smith Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning A. O. Smith; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HPACO-45 1**+AXST-50T 1**?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to A. O. Smith HPACO-45 1**+AXST-50T 1**'s gallon capacity and 3.52 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American MHPCO-45 1**+MXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
Giant GHPCO-45 1**+GXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
John Wood JWHPCO-45 1**+JWXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
American MHPCO-45 1**+MXST-50TTTP 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923

Who Is A. O. Smith HPACO-45 1**+AXST-50T 1** Best For — and When Should You Pick American MHPCO-45 1**+MXST-50T 1**?

Evaluate whether A. O. Smith HPACO-45 1**+AXST-50T 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • A. O. Smith HPACO-45 1**+AXST-50T 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPACO-45 1**+AXST-50T 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPACO-45 1**+AXST-50T 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American MHPCO-45 1**+MXST-50T 1** footprint.

Common Homeowner Questions for A. O. Smith HPACO-45 1**+AXST-50T 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith HPACO-45 1**+AXST-50T 1** records 3.52 UEF (Pass: +1.22 / +53.0%), placing #441 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does A. O. Smith HPACO-45 1**+AXST-50T 1** fit inside a tight hallway closet or low-headroom utility room?

A. O. Smith HPACO-45 1**+AXST-50T 1** requires room for its 57 in. vertical shell and 16 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern A. O. Smith HPACO-45 1**+AXST-50T 1**?

For A. O. Smith HPACO-45 1**+AXST-50T 1**, plan a 240V circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for A. O. Smith HPACO-45 1**+AXST-50T 1**?

Using 923 kWh/yr, A. O. Smith HPACO-45 1**+AXST-50T 1** generates an estimated $168/yr electric bill at 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF)?

A. O. Smith HPACO-45 1**+AXST-50T 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or American MHPCO-45 1**+MXST-50T 1**.

What hot-water delivery rating governs A. O. Smith HPACO-45 1**+AXST-50T 1**?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), A. O. Smith HPACO-45 1**+AXST-50T 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen A. O. Smith HPACO-45 1**+AXST-50T 1** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to A. O. Smith HPACO-45 1**+AXST-50T 1** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is American MHPCO-45 1**+MXST-50T 1** (3.52 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks