American MHPCO-45 1**+MXST-50TTTP 1** Water Heater Specifications (3.52 UEF)

The American MHPCO-45 1**+MXST-50TTTP 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.52 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, ranking #441 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4529450). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.22 / +53.0%. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

Uniform Energy Factor
3.52 UEF
Cohort UEF Rank
#441 of 706
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.22 / +53.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American MHPCO-45 1**+MXST-50TTTP 1** at 3.52 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30American MHPCO-45 1**+MXST-50TTTP 1**: 3.52
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American MHPCO-45 1**+MXST-50TTTP 1** relative to the cohort median.
Efficiency comparison & rule summary

American MHPCO-45 1**+MXST-50TTTP 1** (3.52 UEF) ranks #441 of 706 Hybrid/Electric Heat Pump models — 40-way tie; more efficient than 32% of Hybrid/Electric Heat Pump models, -0.18 UEF below the 3.70 UEF median.

Federal 2029 margin for American MHPCO-45 1**+MXST-50TTTP 1**: +1.22 UEF (+53.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for American MHPCO-45 1**+MXST-50TTTP 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for American MHPCO-45 1**+MXST-50TTTP 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: American MHPCO-45 1**+MXST-50TTTP 1** (3.52 UEF) compares closely with A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF, at parity) and Giant GHPCO-45 1**+GXST-50T 1** (3.52 UEF, at parity).

How Complete Are the Certified Metrics for American MHPCO-45 1**+MXST-50TTTP 1**?

Standing at #441 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, American MHPCO-45 1**+MXST-50TTTP 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 4529450
Model NumberMHPCO-45 1**+MXST-50TTTP 1**Draw pattern: Medium-UsageMHPCO-45 1**+MXST-50TTTP 1**
Uniform Energy Factor (UEF)3.52-0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use923 kWh/yr-149 kWh/yr vs. 1,072 kWh/yr medianEst. $168/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency413%-16.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57" H x 16" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

What Is the Projected Utility Bill for MHPCO-45 1**+MXST-50TTTP 1** by State?

At 923 kWh/yr, American MHPCO-45 1**+MXST-50TTTP 1** averages about $168/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (923 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$168.00/yrHawaii$435.00/yrCalifornia$275.00/yrTexas$147.00/yrWashington$135.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $168/yr $1,676 $4,736
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $435/yr $4,355 $12,305
California 29.75 ¢/kWh ($0.2975) $275/yr $2,746 $7,759
Texas 15.91 ¢/kWh ($0.1591) $147/yr $1,468 $4,149
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $135/yr $1,350 $3,816
Estimated electricity spend (923 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are American Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to MHPCO-45 1**+MXST-50TTTP 1**?

Ordered by minimal capacity and UEF spread relative to American MHPCO-45 1**+MXST-50TTTP 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
Giant GHPCO-45 1**+GXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
John Wood JWHPCO-45 1**+JWXST-50T 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923
A. O. Smith HPACO-45 1**+AXST-50TTTP 1** Hybrid/Electric Heat Pump 45 gal 67 gal 3.52 (at parity) 923

What Are the Limitations of American MHPCO-45 1**+MXST-50TTTP 1** and Who Should Not Install It?

Before ordering American MHPCO-45 1**+MXST-50TTTP 1** (Hybrid/Electric Heat Pump, 3.52 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • American MHPCO-45 1**+MXST-50TTTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American MHPCO-45 1**+MXST-50TTTP 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American MHPCO-45 1**+MXST-50TTTP 1** Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50T 1** footprint.

Practical Specs & Code Questions for American MHPCO-45 1**+MXST-50TTTP 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does American MHPCO-45 1**+MXST-50TTTP 1** pass the May 6, 2029 federal DOE efficiency rule?

American MHPCO-45 1**+MXST-50TTTP 1** carries a verified 3.52 UEF rating (Pass: +1.22 / +53.0%), ranking #441 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does American MHPCO-45 1**+MXST-50TTTP 1** need?

American MHPCO-45 1**+MXST-50TTTP 1** stands 57 in. high with a 16 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does American MHPCO-45 1**+MXST-50TTTP 1** require?

American MHPCO-45 1**+MXST-50TTTP 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does American MHPCO-45 1**+MXST-50TTTP 1** cost per year to run?

Rated at 923 kWh/yr, American MHPCO-45 1**+MXST-50TTTP 1** costs about $168/yr ($1,680 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).

Who should NOT install American MHPCO-45 1**+MXST-50TTTP 1**, and what are its limits?

American MHPCO-45 1**+MXST-50TTTP 1** (3.52 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can American MHPCO-45 1**+MXST-50TTTP 1** serve at peak demand?

American MHPCO-45 1**+MXST-50TTTP 1** achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for American MHPCO-45 1**+MXST-50TTTP 1**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to American MHPCO-45 1**+MXST-50TTTP 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks