American PG10 34 100 2*V 2** Water Heater Specifications (0.9 UEF)
With PD 2408703 certification, American PG10 34 100 2*V 2** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.9 UEF rating across its 33-gallon nominal tank, 170 gal First Hour Rating, standing #2 of 71 across 71 peers with Pass: +0.32 / +55.2% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GSP-100 2** (0.9 UEF).
- Uniform Energy Factor
- 0.9 UEF
- Cohort UEF Rank
- #2 of 71 (top 9.9%)
- First Hour Rating
- 170 gal
- Storage Volume
- 33 gal
- Fuel / Type
- Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.32 / +55.2%

ENERGY STAR certification places American PG10 34 100 2*V 2** at 0.9 UEF (#2 of 71; +0.02 UEF vs. 0.88 UEF median) in Gas-fired Storage Residential-duty Commercial.
American pg10 34 100 2*v 2** stores 33 gal nominal; 170 gal first hour rating (+34 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).
In the Gas-fired Storage Residential-duty Commercial tier, A. O. Smith GSP-100 2** (0.9 UEF, at parity) and State GHX-34-100 N 2** (0.9 UEF, at parity) bracket American PG10 34 100 2*V 2**.
Which Specs Set American PG10 34 100 2*V 2** Apart From Cohort Averages?
Ranked #2 of 71 (top 9.9%) inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, American PG10 34 100 2*V 2** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408703 |
| Model Number | PG10 34 100 2*V 2** | Draw pattern: High-Usage | PG10 34 100 2*V 2** |
| Uniform Energy Factor (UEF) | 0.9 | +0.02 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 170 gal | +34 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 95% | At 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 49" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |
What Should American Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to American; verify whether your PG10 34 100 2*V 2** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?
Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith GSP-100 2** | Gas-fired Storage Residential-duty Commercial | 33 gal | 170 gal | 0.9 (at parity) | — |
| State GHX-34-100 N 2** | Gas-fired Storage Residential-duty Commercial | 33 gal | 170 gal | 0.9 (at parity) | — |
| HTP PH76-50**** | Gas-fired Storage Residential-duty Commercial | 48 gal | 154 gal | 0.9 (at parity) | — |
| GSW WATER HEATERS 6G5076NVC 1** | Gas-fired Storage Residential-duty Commercial | 48 gal | 119 gal | 0.88 (-0.02) | — |
| A. O. Smith GPHE-50 1** | Gas-fired Storage Residential-duty Commercial | 48 gal | 119 gal | 0.88 (-0.02) | — |
What Are the Limitations of American PG10 34 100 2*V 2** and Who Should Not Install It?
Before ordering American PG10 34 100 2*V 2** (Gas-fired Storage Residential-duty Commercial, 0.9 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- American PG10 34 100 2*V 2** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect American PG10 34 100 2*V 2**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 170 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: American PG10 34 100 2*V 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does American PG10 34 100 2*V 2** pass the May 6, 2029 federal DOE efficiency rule?
American PG10 34 100 2*V 2** carries a verified 0.9 UEF rating (Pass: +0.32 / +55.2%), ranking #2 of 71 (top 9.9%) across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.
What doorway width and ceiling height does American PG10 34 100 2*V 2** need?
American PG10 34 100 2*V 2** stands 49 in. high with a 22 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does American PG10 34 100 2*V 2** require?
American PG10 34 100 2*V 2** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.
How much electricity or energy does American PG10 34 100 2*V 2** cost per year to run?
ENERGY STAR rates American PG10 34 100 2*V 2** as a Natural Gas, Propane heater (0.9 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.
Who should NOT install American PG10 34 100 2*V 2**, and what are its limits?
American PG10 34 100 2*V 2** (0.9 UEF) is not suited for multi-bath marathon draws exceeding its 170 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.
How many bathrooms or people can American PG10 34 100 2*V 2** serve at peak demand?
American PG10 34 100 2*V 2** achieves a 170 gal First Hour Rating (+34 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for American PG10 34 100 2*V 2**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to American PG10 34 100 2*V 2**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith GSP-100 2** (0.9 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)