Skip to main content
ENERGY STAR water heater model · PD 2408701

A. O. Smith GSP-100 2** Water Heater Specifications (0.9 UEF)

Certified at 0.9 UEF across its 33-gallon nominal tank, 170 gal First Hour Rating, A. O. Smith GSP-100 2** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) places #2 of 71 out of 71 ENERGY STAR models (PD 2408701). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.32 / +55.2%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is American PG10 34 100 2*V 2** (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#2 of 71 (top 9.9%)
First Hour Rating
170 gal
Storage Volume
33 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking A. O. Smith GSP-100 2** at 0.9 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58A. O. Smith GSP-100 2**: 0.90
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows A. O. Smith GSP-100 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.9 UEF, A. O. Smith GSP-100 2** places #2 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations (+0.02 UEF vs. 0.88 UEF median).

A. o. smith gsp-100 2** stores 33 gal nominal; 170 gal first hour rating (+34 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

Closest alternatives to A. O. Smith GSP-100 2** include American PG10 34 100 2*V 2** (0.9 UEF, at parity) alongside State GHX-34-100 N 2** (0.9 UEF, at parity).

What Physical and Thermal Ratings Define A. O. Smith GSP-100 2**?

Positioning at #2 of 71 (top 9.9%) out of 71 Gas-fired Storage Residential-duty Commercial peers, A. O. Smith GSP-100 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2408701
Model NumberGSP-100 2**Draw pattern: High-UsageGSP-100 2**
Uniform Energy Factor (UEF)0.9+0.02 UEF vs. 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)170 gal+34 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency95%At 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)49" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any A. O. Smith Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to A. O. Smith GSP-100 2**?

Homeowners cross-shopping A. O. Smith GSP-100 2** frequently review these five Gas-fired Storage Residential-duty Commercial models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American PG10 34 100 2*V 2** Gas-fired Storage Residential-duty Commercial 33 gal 170 gal 0.9 (at parity) —
State GHX-34-100 N 2** Gas-fired Storage Residential-duty Commercial 33 gal 170 gal 0.9 (at parity) —
HTP PH76-50**** Gas-fired Storage Residential-duty Commercial 48 gal 154 gal 0.9 (at parity) —
GSW WATER HEATERS 6G5076NVC 1** Gas-fired Storage Residential-duty Commercial 48 gal 119 gal 0.88 (-0.02) —
American PR-34-100 * 2** Gas-fired Storage Residential-duty Commercial 33 gal 170 gal 0.9 (at parity) —

What Installation Caveats Apply Before Buying A. O. Smith GSP-100 2**?

Even high-UEF units like A. O. Smith GSP-100 2** (0.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • A. O. Smith GSP-100 2** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect A. O. Smith GSP-100 2**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 170 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for A. O. Smith GSP-100 2** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like American PG10 34 100 2*V 2**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Sizing, Efficiency & Recall Answers for A. O. Smith GSP-100 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith GSP-100 2** eligible for continued manufacture past May 6, 2029?

At 0.9 UEF, A. O. Smith GSP-100 2** achieves Pass: +0.32 / +55.2% for the 2029 DOE standard and stands #2 of 71 (top 9.9%) against American PG10 34 100 2*V 2** and State GHX-34-100 N 2**.

How tall and wide is A. O. Smith GSP-100 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith GSP-100 2** are 49 in. height and 22 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d)); verify stair turns and drain pan width before delivery.

Will A. O. Smith GSP-100 2** require upgrading household electrical panels or gas piping?

Check Natural Gas, Propane piping and venting for A. O. Smith GSP-100 2** (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is A. O. Smith GSP-100 2** economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for A. O. Smith GSP-100 2** (Natural Gas, Propane, 0.9 UEF) hinge on household gallon demand and local gas utility tariffs compared with American PG10 34 100 2*V 2**.

Which installation bottlenecks limit A. O. Smith GSP-100 2**?

Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.32 / +55.2%) and physical doorway clearances before choosing A. O. Smith GSP-100 2** over American PG10 34 100 2*V 2**.

How does A. O. Smith GSP-100 2** handle simultaneous showers and laundry?

Delivering 170 gal in the first hour (+34 gal vs. 136 gal median), A. O. Smith GSP-100 2** combines 33 gal tank storage with rapid burner/element recovery.

How long is the warranty on A. O. Smith GSP-100 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith GSP-100 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas-fired Storage Residential-duty Commercial is American PG10 34 100 2*V 2** (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks