American PR-34-100 * 2** Water Heater Specifications (0.9 UEF)
Engineered as a Natural Gas, Propane Gas-fired Storage Residential-duty Commercial unit, American PR-34-100 * 2** achieves a certified 0.9 UEF rating across its 33-gallon nominal tank, 170 gal First Hour Rating and ranks #2 of 71 in its 71-model cohort (PD 2408702), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GSP-100 2** (0.9 UEF).
- Uniform Energy Factor
- 0.9 UEF
- Cohort UEF Rank
- #2 of 71 (top 9.9%)
- First Hour Rating
- 170 gal
- Storage Volume
- 33 gal
- Fuel / Type
- Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.32 / +55.2%

Within the 71-unit Gas-fired Storage Residential-duty Commercial cohort, American PR-34-100 * 2** logs 0.9 UEF and ranks #2 of 71.
American pr-34-100 * 2** stores 33 gal nominal; 170 gal first hour rating (+34 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).
Cross-shopping American PR-34-100 * 2** (0.9 UEF)? Check A. O. Smith GSP-100 2** (0.9 UEF, at parity) and State GHX-34-100 N 2** (0.9 UEF, at parity).
How Complete Are the Certified Metrics for American PR-34-100 * 2**?
Standing at #2 of 71 (top 9.9%) among 71 certified Gas-fired Storage Residential-duty Commercial heaters, American PR-34-100 * 2** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408702 |
| Model Number | PR-34-100 * 2** | Draw pattern: High-Usage | PR-34-100 * 2** |
| Uniform Energy Factor (UEF) | 0.9 | +0.02 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 170 gal | +34 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 95% | At 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 49" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |
Are American Models Affected by Current CPSC Notices?
Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to PR-34-100 * 2**?
Ordered by minimal capacity and UEF spread relative to American PR-34-100 * 2**, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith GSP-100 2** | Gas-fired Storage Residential-duty Commercial | 33 gal | 170 gal | 0.9 (at parity) | — |
| State GHX-34-100 N 2** | Gas-fired Storage Residential-duty Commercial | 33 gal | 170 gal | 0.9 (at parity) | — |
| HTP PH76-50**** | Gas-fired Storage Residential-duty Commercial | 48 gal | 154 gal | 0.9 (at parity) | — |
| GSW WATER HEATERS 6G5076NVC 1** | Gas-fired Storage Residential-duty Commercial | 48 gal | 119 gal | 0.88 (-0.02) | — |
| A. O. Smith GPHE-50 1** | Gas-fired Storage Residential-duty Commercial | 48 gal | 119 gal | 0.88 (-0.02) | — |
Who Is American PR-34-100 * 2** Best For — and When Should You Pick A. O. Smith GSP-100 2**?
Evaluate whether American PR-34-100 * 2**'s Gas-fired Storage Residential-duty Commercial architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- American PR-34-100 * 2** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect American PR-34-100 * 2**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 170 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Practical Specs & Code Questions for American PR-34-100 * 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does American PR-34-100 * 2** (0.9 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American PR-34-100 * 2** records 0.9 UEF (Pass: +0.32 / +55.2%), placing #2 of 71 (top 9.9%) out of 71 certified Gas-fired Storage Residential-duty Commercial configurations.
Does American PR-34-100 * 2** fit inside a tight hallway closet or low-headroom utility room?
American PR-34-100 * 2** requires room for its 49 in. vertical shell and 22 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern American PR-34-100 * 2**?
Installing American PR-34-100 * 2** on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.
What annual utility bill should homeowners budget for American PR-34-100 * 2**?
Rated 0.9 UEF on Natural Gas, Propane, American PR-34-100 * 2** carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas-fired Storage Residential-duty Commercial models.
What are the main drawbacks of American PR-34-100 * 2** (0.9 UEF)?
Buyers expecting endless simultaneous shower flow beyond 170 gal should compare condensing tankless units or larger-capacity tanks.
What hot-water delivery rating governs American PR-34-100 * 2**?
Rated for 170 gal FHR (+34 gal vs. 136 gal median), American PR-34-100 * 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen American PR-34-100 * 2** for recalls and tank age?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to American PR-34-100 * 2** in the Gas-fired Storage Residential-duty Commercial class?
Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith GSP-100 2** (0.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)