Skip to main content
ENERGY STAR water heater model · PD 2408702

American PR-34-100 * 2** Water Heater Specifications (0.9 UEF)

Engineered as a Natural Gas, Propane Gas-fired Storage Residential-duty Commercial unit, American PR-34-100 * 2** achieves a certified 0.9 UEF rating across its 33-gallon nominal tank, 170 gal First Hour Rating and ranks #2 of 71 in its 71-model cohort (PD 2408702), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GSP-100 2** (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#2 of 71 (top 9.9%)
First Hour Rating
170 gal
Storage Volume
33 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking American PR-34-100 * 2** at 0.9 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58American PR-34-100 * 2**: 0.90
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows American PR-34-100 * 2** relative to the cohort median.
Efficiency comparison & rule summary

Within the 71-unit Gas-fired Storage Residential-duty Commercial cohort, American PR-34-100 * 2** logs 0.9 UEF and ranks #2 of 71.

American pr-34-100 * 2** stores 33 gal nominal; 170 gal first hour rating (+34 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

Cross-shopping American PR-34-100 * 2** (0.9 UEF)? Check A. O. Smith GSP-100 2** (0.9 UEF, at parity) and State GHX-34-100 N 2** (0.9 UEF, at parity).

How Complete Are the Certified Metrics for American PR-34-100 * 2**?

Standing at #2 of 71 (top 9.9%) among 71 certified Gas-fired Storage Residential-duty Commercial heaters, American PR-34-100 * 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408702
Model NumberPR-34-100 * 2**Draw pattern: High-UsagePR-34-100 * 2**
Uniform Energy Factor (UEF)0.9+0.02 UEF vs. 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)170 gal+34 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency95%At 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)49" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are American Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to PR-34-100 * 2**?

Ordered by minimal capacity and UEF spread relative to American PR-34-100 * 2**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith GSP-100 2** Gas-fired Storage Residential-duty Commercial 33 gal 170 gal 0.9 (at parity) —
State GHX-34-100 N 2** Gas-fired Storage Residential-duty Commercial 33 gal 170 gal 0.9 (at parity) —
HTP PH76-50**** Gas-fired Storage Residential-duty Commercial 48 gal 154 gal 0.9 (at parity) —
GSW WATER HEATERS 6G5076NVC 1** Gas-fired Storage Residential-duty Commercial 48 gal 119 gal 0.88 (-0.02) —
A. O. Smith GPHE-50 1** Gas-fired Storage Residential-duty Commercial 48 gal 119 gal 0.88 (-0.02) —

Who Is American PR-34-100 * 2** Best For — and When Should You Pick A. O. Smith GSP-100 2**?

Evaluate whether American PR-34-100 * 2**'s Gas-fired Storage Residential-duty Commercial architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • American PR-34-100 * 2** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect American PR-34-100 * 2**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 170 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for American PR-34-100 * 2** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GSP-100 2**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Practical Specs & Code Questions for American PR-34-100 * 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does American PR-34-100 * 2** (0.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American PR-34-100 * 2** records 0.9 UEF (Pass: +0.32 / +55.2%), placing #2 of 71 (top 9.9%) out of 71 certified Gas-fired Storage Residential-duty Commercial configurations.

Does American PR-34-100 * 2** fit inside a tight hallway closet or low-headroom utility room?

American PR-34-100 * 2** requires room for its 49 in. vertical shell and 22 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern American PR-34-100 * 2**?

Installing American PR-34-100 * 2** on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for American PR-34-100 * 2**?

Rated 0.9 UEF on Natural Gas, Propane, American PR-34-100 * 2** carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas-fired Storage Residential-duty Commercial models.

What are the main drawbacks of American PR-34-100 * 2** (0.9 UEF)?

Buyers expecting endless simultaneous shower flow beyond 170 gal should compare condensing tankless units or larger-capacity tanks.

What hot-water delivery rating governs American PR-34-100 * 2**?

Rated for 170 gal FHR (+34 gal vs. 136 gal median), American PR-34-100 * 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen American PR-34-100 * 2** for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to American PR-34-100 * 2** in the Gas-fired Storage Residential-duty Commercial class?

Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith GSP-100 2** (0.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks