Skip to main content
ENERGY STAR water heater model · PD 3722795

Bosch TR7000T-65CA Water Heater Specifications (3.9 UEF)

The Bosch TR7000T-65CA (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.9 UEF rating across its 60-gallon nominal tank, 80 gal First Hour Rating, ranking #144 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3722795). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.40 / +56.0%. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Custom Comfort CCOHPWH65A (3.9 UEF).

Uniform Energy Factor
3.9 UEF
Cohort UEF Rank
#144 of 706 (top 22.9%)
First Hour Rating
80 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.40 / +56.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Bosch TR7000T-65CA at 3.9 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Bosch TR7000T-65CA: 3.90
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Bosch TR7000T-65CA relative to the cohort median.
Efficiency comparison & rule summary

Bosch TR7000T-65CA (3.9 UEF) ranks #144 of 706 Hybrid/Electric Heat Pump models — 19-way tie; top 22.9%, more efficient than 77.1% of Hybrid/Electric Heat Pump models, +0.20 UEF above the 3.70 UEF median.

Federal 2029 margin for Bosch TR7000T-65CA: +1.40 UEF (+56.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Bosch TR7000T-65CA runs ~$225/yr vs. ~$955/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Bosch TR7000T-65CA: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Bosch TR7000T-65CA (3.9 UEF) compares closely with Custom Comfort CCOHPWH65A (3.9 UEF, at parity) and Eco-Logical ECO-65HPM1A (3.9 UEF, at parity).

What Physical and Thermal Ratings Define Bosch TR7000T-65CA?

Positioning at #144 of 706 (top 22.9%) out of 706 Hybrid/Electric Heat Pump peers, Bosch TR7000T-65CA pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandBosch12 certified listingsENERGY STAR PD 3722795
Model NumberTR7000T-65CADraw pattern: High-UsageTR7000T-65CA
Uniform Energy Factor (UEF)3.9+0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)80 gal+8 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)45.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2025-01-16Certified 2025-01-16Markets: Canada

Why Do State Utility Rates Shift TR7000T-65CA Running Costs?

Consuming 1,240 kWh annually puts Bosch TR7000T-65CA near $225/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,295
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $18,952
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $11,951
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,391
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $5,877
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Bosch Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Bosch; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Bosch TR7000T-65CA?

Homeowners cross-shopping Bosch TR7000T-65CA frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Custom Comfort CCOHPWH65A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Eco-Logical ECO-65HPM1A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Kepler AZMCHW-65VN3A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Midea CAN3-RSJ-15/250RDVN3-L3 Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240
Midea MAHW-65VN3A Hybrid/Electric Heat Pump 60 gal 80 gal 3.9 (at parity) 1,240

What Installation Caveats Apply Before Buying Bosch TR7000T-65CA?

Even high-UEF units like Bosch TR7000T-65CA (3.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Bosch TR7000T-65CA needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Bosch TR7000T-65CA directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Bosch TR7000T-65CA Strong Fit — 3.9 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Custom Comfort CCOHPWH65A footprint.

Sizing, Efficiency & Recall Answers for Bosch TR7000T-65CA

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Bosch TR7000T-65CA eligible for continued manufacture past May 6, 2029?

At 3.9 UEF, Bosch TR7000T-65CA achieves Pass: +1.40 / +56.0% for the 2029 DOE standard and stands #144 of 706 (top 22.9%) against Custom Comfort CCOHPWH65A and Eco-Logical ECO-65HPM1A.

How tall and wide is Bosch TR7000T-65CA, and what service clearance is needed?

Physical dimensions for Bosch TR7000T-65CA are 45.5 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

Will Bosch TR7000T-65CA require upgrading household electrical panels or gas piping?

Bosch TR7000T-65CA draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Bosch TR7000T-65CA economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $225/yr ($2,250 over 10 years) to power Bosch TR7000T-65CA at 1,240 kWh/yr under the 18.16 cents/kWh US average (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

Which installation bottlenecks limit Bosch TR7000T-65CA?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Bosch TR7000T-65CA drops into resistance mode more often.

How does Bosch TR7000T-65CA handle simultaneous showers and laundry?

Delivering 80 gal in the first hour (+8 gal vs. 72 gal median), Bosch TR7000T-65CA combines 60 gal tank storage with rapid burner/element recovery.

How long is the warranty on Bosch TR7000T-65CA and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Bosch as of 2026-11-23. Confirm install proof and serial manufacture year on Bosch TR7000T-65CA before calling service.

How do 2026 post-OBBBA rebates affect buying Bosch TR7000T-65CA?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Custom Comfort CCOHPWH65A (3.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks